On 05/28/2015 03:26 PM, Vangelis Kyriakakis wrote: > I would like to know if the ServerTACACSPLUS is compatible with > Farmsize X. Is it possible to have more farm childs serving TCP port 49?
Yes, that's possible. Please see goodies/tacacsplusserver.cfg in Radiator 4.14 distribution and look for AllowAuthorizeOnly. There's the option and a Handler related to it. With FarmSize, the initial authentication (if TACACS+ used for auth) and the subsequent authorization requests can be processed by different farm workers. The above option allows radiusd to query the backend for authorization requests even if it has not received requests for the user yet. The option defaults to disable and it's intended for FarmSize or configurations where, for example, authentication is not done with TACACS+ Thanks, Heikki -- Heikki Vatiainen <h...@open.com.au> Radiator: the most portable, flexible and configurable RADIUS server anywhere. SQL, proxy, DBM, files, LDAP, NIS+, password, NT, Emerald, Platypus, Freeside, TACACS+, PAM, external, Active Directory, EAP, TLS, TTLS, PEAP, TNC, WiMAX, RSA, Vasco, Yubikey, MOTP, HOTP, TOTP, DIAMETER etc. Full source on Unix, Windows, MacOSX, Solaris, VMS, NetWare etc. _______________________________________________ radiator mailing list radiator@open.com.au http://www.open.com.au/mailman/listinfo/radiator