These are all from an EX2200-C-12T-2G's, running 12.3R12.4 We're stuck at that release for the 2200-C's, as 15.x bricks them in our environment (TSB17138 does warn to not use 15.x).
> I just saw your comment in the patch that N/A only appeared for a temperature > in the range -1 to 0. Correct - last I dug into this, it only reports N/A at 0 (zero), and -1 degrees. It always struck me as an odd cosmetic. -----Original Message----- From: Rancid-discuss [mailto:rancid-discuss-boun...@shrubbery.net] On Behalf Of Anderson, Charles R Sent: Wednesday, February 20, 2019 9:20 AM To: rancid-discuss@shrubbery.net Subject: Re: [rancid] [PATCH] junos.pm: filter negative temperatures in ShowChassisEnvironment My example below WAS from an EX2200. We have some others that always report -10 (even in toasty closets)--I wonder if that is off-scale low due to a sensor failure? I have also seen N/A in 2016, but not lately. What software version are you running? We are running 12.3R12-S2 on this particular outdoor EX2200. I can try to find out what version we were running in 2016 when we last saw N/A. I just saw your comment in the patch that N/A only appeared for a temperature in the range -1 to 0. On Wed, Feb 20, 2019 at 08:54:39AM -0800, Emille Blanc wrote: > Ironically, we rely on RANCID to tell us when our cabinets get too cold on > such devices. > Mostly because our NMS is hopeless, and can't do it (Enterprise! Closed > source!), so it never occurred to me to submit a patch for this. > > However, some devices (namely, EX2200's) don't understand zero, or sub-zero > degrees and report it as N/A. > I've attached a patch to cover this circumstance. > > # Class Item Status > # Power FPC 0 Power Supply 0 OK > # Temp FPC 0 GEPHY1 OK > - # FPC 0 GEPHY2 OK N/A > + # FPC 0 GEPHY2 OK > # FPC 0 GEPHY3 OK > # FPC 0 GEPHY4 OK > # > > -----Original Message----- > From: Rancid-discuss [mailto:rancid-discuss-boun...@shrubbery.net] On Behalf > Of Anderson, Charles R > Sent: Tuesday, February 19, 2019 6:50 AM > To: rancid-discuss@shrubbery.net > Subject: [rancid] [PATCH] junos.pm: filter negative temperatures in > ShowChassisEnvironment > > One of our switches is in an outdoor cabinet. It gets below 0 sometimes so > we see output like this: > > # Temp FPC 0 GEPHY1 OK > # FPC 0 GEPHY2 OK > # FPC 0 GEPHY3 OK > - # FPC 0 GEPHY4 OK -5 degrees C / 23 degrees > F > + # FPC 0 GEPHY4 OK > # > > The attached patch fixes ShowChassisEnvironment so it matches the - sign. _______________________________________________ Rancid-discuss mailing list Rancid-discuss@shrubbery.net http://www.shrubbery.net/mailman/listinfo/rancid-discuss _______________________________________________ Rancid-discuss mailing list Rancid-discuss@shrubbery.net http://www.shrubbery.net/mailman/listinfo/rancid-discuss