Jim,

Follow these steps to take care of this:

01. Search ALL Command Files, Start-Up files and EEPs 
    for the Variable in question and its data type.

02. In Form Designer:

    . Check the Expressions in Form for Pre-Defined 
      Variable (if any) 

    . Delete the Field

    . Save the form

03. At the Mighty R> Prompt:

    R> CLEAR ALL VAR

    R> SET VAR vConID INTEGER = NULL

    R> FORM FormName 

04. In Form Designer ... again ...

    . Place a variable object on the form (vConID)

    . Change Field Order accordingly ...

    . Save the form.

Enjoy and make sure to have fun with The Glorious 
R:BASE 2000 (ver 6.5+) for Windows!

Very Best Regards,

Razzak.

At 05:17 PM 6/8/2001 -0400, Jim Andrus wrote:

>RBWin 2000, Ver 6.5+

>... I then get the error message:
>"Your value does not have the same type or scale as your 
>variable (2178)"....


===================================-============================
R:BASE Developers's Conference: http://www.rbase.com/conference 
Official R:BASE List Server:    mailto:[EMAIL PROTECTED]
RBTI Events/Training:        http://www.rbase2000.com/events
R:DCC Members:               http://www.rbase2000.com/rdcc
================================================================
R:BASE, Oterro & R:Tango are registered trademarks of RBTI.
==================================-=============================

Reply via email to