At 08:54 AM 12/11/2002 -0500, J.M. GRATIAS wrote:

Razzak :

>>
02.     At the R> Prompt:
         SET AUTOUPGRADE ON
         SET AUTOCONVERT ON
         SET STATICDB OFF (in case your RBASE.CFG default is SET to ON)
         CONNECT DBName IDENTIFIED BY UserID Password
03.     LIST SYS%
         You SHOULD be able to see the following additional five (5)
tables:
         SYS_FORMS3
         SYS_LABELS3
         SYS_LAYOUTS3
         SYS_MERGE
         SYS_REPORTS3
<<

What hapen if we don't autoupgrade/autoconvert as long as we stay with
RBW6.5++ (1.862xRT03 and later if any) ?
Can we delayed the creation of thoses new table until RGB7 installation ?

J.M.,

01.     Those five (5) new system tables will let you work simultaneously
        with The Glorious R:BASE 2000 (ver 6.5++), Build:1.862xRT03
        (DOS/Windows) and The Magical R:BASE 7.0 for Windows.

        That way, you can use 6.5++ DOS/Windows versions and also
        enjoy the head-start and design 7.0 applications at the same time.

02.     If you would like to use your database for 6.5++ exclusive use Only,
        then,  you don't need to follow those steps to create those system
        tables.

Very Best Regards,

Razzak.


================================================