At 04:23 PM 1/19/2005, Stephen Markson wrote:
I had reported a bug about SKIP not working and the response I got from RDCC was that SKIP is not supported any longer, but PROPERTY componentID SET_FOCUS 'TRUE' is. My experience is that both work well.
Stephen,
Both "SKIP TO" and "SET_FOCUS" should work accordingly in the latest versions of R:BASE.
Currently, "SKIP TO fieldname" or "SKIP n" options are not supported in an EEP when used in Scrolling Region control.
Future updates/versions of R:BASE 7.x/V-8 "Turbo" will support that.
And this bug of SET_FOCUS not working when a form starts is not a bug! I just found out that the anomalous behaviour occured when I was TRACing program. When I RUN the program everything works fine. So, never mind.
Thanks for the clarification!
In my reported bug, I found that the SKIP and SET_FOCUS both do not work when the EEP had a DIALOG command.
What exact version and build of R:BASE 7.1 are you using?
Maybe I need to do something about SCREEN RESTORE?
FYI, SCREEN RESTORE command is now DOS Only.
For more details, take a look at the section on "Obsolete Commands" in R:BASE 7.x for Windows. Here's how:
At the mighty R> Prompt, type:
HELP OBSOLETE
Very Best R:egards,
Razzak.