Wrenchers,
Does anyone have feedback on using TS4R-F for rapid shutdown? It was a
tough run for us with RMA's on the SMA Rapid Shutdown boxes. We never
messed around with Tigo but have followed threads here, and recently had an
SMA tech tell me "he wouldn't wish it on his worst enemy". Probably going
to give the TS4R-F a shot with some SMA installs but interested to hear any
feedback on product reliability. Thanks for any thoughts.
Adam