Thanks, Harry.

A cut to the chase question, please: is there a Core
inverter-compatible/acceptable RSD product that can accommodate mods with a
60+ VOC?

Mahalo,
marco

On Friday, March 18, 2022, Harry Mahon <michael.ma...@sma-america.com>
wrote:

> All – A few points of clarification.
>
>
>
> There are no Tigo devices on the SunSpec CERTIFIED list of rapid shutdown
> receivers (which can be found at Sunspec.org).
>
> Thus, SMA will not go through any compatibility testing with Tigo devices
> that are stated to be SunSpec compatible (any TIGO device with F at end of
> name)
>
>
>
> So, the statement that SMA does not approve of any Tigo devices paired
> with SMA inverters is correct *** when using SunSpec for rapid shutdown ***.
>
>
>
> The Sunny Boy US-41 and CORE1 US-41 lines have built into every unit a
> SunSpec certified (found on SunSpec.org) rapid shutdown transmitter.
>
> So only when used with SMA approved SunSpec certified rapid shutdown
> receivers is this a fully supported installation by SMA Service line.
>
>
>
> The list of SMA approved receivers can be found on the respective CORE and
> Sunny Boy product pages at SMA-America.com. Go to the Downloads tab, the
> Background Knowledge section, and look for “Technical Information – SunSpec
> Certified Rapid Shutdown Devices”
>
> Direct link to current SMA approved SunSpec receiver document:
> https://files.sma.de/downloads/SunSpec-Kompatibilitaet-TI-en-14.pdf
>
>
>
> This approved list was created to ensure ALL inverter functions perform as
> expected when SunSpec signalling is used for rapid shutdown. SunSpec
> certification for rapid shutdown only covers the rapid shutdown
> functionality. As new rapid shutdown receivers are certified by SunSpec,
> SMA goes through our approval testing. So the above document is updated
> regularly – please check SMA-America.com for the most up-to-date version
> rather than keeping the above link.
>
>
>
> The TS4-A-O unit from Tigo does not use SunSpec for rapid shutdown
> compliance.  That device (also requiring an external CCA separately wired
> to TAP unit(s) near array to provide rapid shutdown compliance) ARE
> approved for use with both the Sunny Boy US-41 and CORE1 US-41 lines from
> SMA.  This is the ONLY current unit from Tigo that is approved for use with
> current SMA inverters.
>
> ** Note that there is a different setting chosen for Rapid Shutdown during
> SMA inverter commissioning if using the TS4-A-O; it is NOT SunSpec! Please
> contact SMA if you have any questions.**
>
>
>
> Direct link to (no longer updated) TS4 SMA global compatibility document:
> https://files.sma.de/downloads/TS4-Kompatibilitaet-TI-en-19.pdf
>
>
>
> Sharp eyed readers will note that the above linked document mentions the
> TS4-R-F-42 unit. This was an SMA-only part as SMA physically modified the
> stock Tigo TS4-R-F to achieve SunSpec certification. The Tigo TS4-R-F was
> not SunSpec certified, and neither are any current TS4-A-F or TS4-A-2F
> units.
>
>
>
> There was a mention of the GIB in the thread, the Gateway Interface Board
> (GIB) was part of the SMA Rooftop Communication Kit P2 that was
> discontinued 4+ years ago. If using the TS4-A-O, external CCA and
> TAP/Gateway are required.
>
>
>
> Best –
>
> Mike
>
>
>
>
> Michael Mahon
> Senior Technical Trainer, Solar Academy
> *SMA America*
>
> 3925 Atherton Rd
> <https://www.google.com/maps/search/3925+Atherton+Rd+%0D%0A+Rocklin,+CA+95765?entry=gmail&source=g>
>
> Rocklin, CA 95765
> <https://www.google.com/maps/search/3925+Atherton+Rd+%0D%0A+Rocklin,+CA+95765?entry=gmail&source=g>
> Mobile:   +1 916 918 9412
> * www.SMA-America.com
> <https://eur02.safelinks.protection.outlook.com/?url=http%3A%2F%2Fwww.sma-america.com%2F&data=04%7C01%7CMichael.Mahon%40sma-america.com%7C7c37bb11c19143be244508d8c4708123%7Ca059b96c28294d1188374cc1ff84735d%7C0%7C0%7C637475334767665428%7CUnknown%7CTWFpbGZsb3d8eyJWIjoiMC4wLjAwMDAiLCJQIjoiV2luMzIiLCJBTiI6Ik1haWwiLCJXVCI6Mn0%3D%7C1000&sdata=Y%2FbXqYrd%2FX9hYC3%2BKsO%2Fn15XWX%2BoatBsL0IwlBOMjBA%3D&reserved=0>*
>
> Solar Academy website
> <https://eur02.safelinks.protection.outlook.com/?url=https%3A%2F%2Fsolaracademy.sma.de%2Fen.html&data=04%7C01%7CMichael.Mahon%40sma-america.com%7C7c37bb11c19143be244508d8c4708123%7Ca059b96c28294d1188374cc1ff84735d%7C0%7C0%7C637475334767675424%7CUnknown%7CTWFpbGZsb3d8eyJWIjoiMC4wLjAwMDAiLCJQIjoiV2luMzIiLCJBTiI6Ik1haWwiLCJXVCI6Mn0%3D%7C1000&sdata=rEzoRJ8HjvBTPJKWI9zqi7e0VkiuRyd9FQalgtOLrdI%3D&reserved=0>
>
> Upcoming SMA America Solar Academy webinars: English
> <https://eur02.safelinks.protection.outlook.com/?url=https%3A%2F%2Fsolaracademy.sma.de%2Fen%2Fcourses.html%3Ffilter%255b1%255d%3DEnglish%26filter%255b2%255d%3DUnited%2520States&data=04%7C01%7CMichael.Mahon%40sma-america.com%7C7c37bb11c19143be244508d8c4708123%7Ca059b96c28294d1188374cc1ff84735d%7C0%7C0%7C637475334767685417%7CUnknown%7CTWFpbGZsb3d8eyJWIjoiMC4wLjAwMDAiLCJQIjoiV2luMzIiLCJBTiI6Ik1haWwiLCJXVCI6Mn0%3D%7C1000&sdata=qwU%2FexGKNX4XJrvnBi6D5ijuK0qarJyghtBVWKQH2iE%3D&reserved=0>
> and Spanish
> <https://eur02.safelinks.protection.outlook.com/?url=https%3A%2F%2Fsolaracademy.sma.de%2Fen%2Fcourses.html%3Ffilter%255b1%255d%3DSpanish%26filter%255b2%255d%3DUnited%2520States&data=04%7C01%7CMichael.Mahon%40sma-america.com%7C7c37bb11c19143be244508d8c4708123%7Ca059b96c28294d1188374cc1ff84735d%7C0%7C0%7C637475334767685417%7CUnknown%7CTWFpbGZsb3d8eyJWIjoiMC4wLjAwMDAiLCJQIjoiV2luMzIiLCJBTiI6Ik1haWwiLCJXVCI6Mn0%3D%7C1000&sdata=kjV6E58mxunLvJr2%2BTPS6fSd%2BQlPZm8WqQIbtIeGOGI%3D&reserved=0>
>
>
> <https://eur02.safelinks.protection.outlook.com/?url=http%3A%2F%2Fwww.smainverted.com%2F&data=04%7C01%7CMichael.Mahon%40sma-america.com%7C90309a1470fd4699686008d9514294c8%7Ca059b96c28294d1188374cc1ff84735d%7C0%7C0%7C637630168696828295%7CUnknown%7CTWFpbGZsb3d8eyJWIjoiMC4wLjAwMDAiLCJQIjoiV2luMzIiLCJBTiI6Ik1haWwiLCJXVCI6Mn0%3D%7C1000&sdata=%2BX8GAkfFNXxAxM565oOXOcNt3DnrrE7RzPccsQM2pzs%3D&reserved=0>
>   [image: Linkedin Logo]
> <https://eur02.safelinks.protection.outlook.com/?url=http%3A%2F%2Fwww.linkedin.com%2Fcompany%2F364675&data=04%7C01%7CMichael.Mahon%40sma-america.com%7C90309a1470fd4699686008d9514294c8%7Ca059b96c28294d1188374cc1ff84735d%7C0%7C0%7C637630168696838290%7CUnknown%7CTWFpbGZsb3d8eyJWIjoiMC4wLjAwMDAiLCJQIjoiV2luMzIiLCJBTiI6Ik1haWwiLCJXVCI6Mn0%3D%7C1000&sdata=ywOykswEt%2FvRYn7N7JQ5510g0r7Avp%2FKlBVxcpy9NlY%3D&reserved=0>
>
> <https://eur02.safelinks.protection.outlook.com/?url=http%3A%2F%2Fwww.youtube.com%2Fplaylist%3Flist%3DPL840A5336CAC32332&data=04%7C01%7CMichael.Mahon%40sma-america.com%7C90309a1470fd4699686008d9514294c8%7Ca059b96c28294d1188374cc1ff84735d%7C0%7C0%7C637630168696848287%7CUnknown%7CTWFpbGZsb3d8eyJWIjoiMC4wLjAwMDAiLCJQIjoiV2luMzIiLCJBTiI6Ik1haWwiLCJXVCI6Mn0%3D%7C1000&sdata=z2mRFQr9f4oVyMhg0Bh02ooRf6UwOH3HET%2FczH2Upko%3D&reserved=0>
>
>
>
> [image: Graphical user interface, text, website Description automatically
> generated]
> <https://eur02.safelinks.protection.outlook.com/?url=https%3A%2F%2Fwww.sma-america.com%2Fshadefix.html&data=04%7C01%7CMichael.Mahon%40sma-america.com%7C6a5e9a55c13f4be16cda08d9e6643a9a%7Ca059b96c28294d1188374cc1ff84735d%7C0%7C0%7C637794140412323660%7CUnknown%7CTWFpbGZsb3d8eyJWIjoiMC4wLjAwMDAiLCJQIjoiV2luMzIiLCJBTiI6Ik1haWwiLCJXVCI6Mn0%3D%7C3000&sdata=xiZdVY8duMb8z87LYBOpuMluD%2FHLrHDGMNXEtWT5QNk%3D&reserved=0>
>
> This email and any attachments thereto may contain SMA America, LLC
> confidential, privileged and private material for the sole use of the
> intended recipient. Any review, copying, or distribution of this email (or
> any attachments thereto) by others is strictly prohibited. If you are not
> the intended recipient, please contact the sender immediately and
> permanently delete the original and any copies of this email and any
> attachments thereto. Thank you.
>
>
>
> *From:* RE-wrenches <re-wrenches-boun...@lists.re-wrenches.org> *On
> Behalf Of *Glenn Burt
> *Sent:* Thursday, March 17, 2022 9:57 PM
> *To:* Marco Mangelsdorf <ma...@pvthawaii.com>; RE-wrenches <
> re-wrenches@lists.re-wrenches.org>
> *Subject:* Re: [RE-wrenches] SMA SBxx-US-41 inverters and Tigo TS4A-O
> operation
>
>
>
> Yes, no SMA products are to be used with Tigo equipment. Turns out they
> are not really fully Sunspec Alliance compatible.
>
> They have tested a couple of products thoroughly with their inverters and
> you can find them on the SMA website.
>
>
>
> Oh and BTW, new SMA inverters will no longer have Wi-Fi capabilities due
> to chip shortages. Another nugget from the class...
>
>
>
> -Glenn
>
> Sent from my 'smart'phone, so please excuse typos and spelling errors.
>
>
>
> ------ Original message------
>
> *From: *Marco Mangelsdorf
>
> *Date: *Thu, Mar 17, 2022 11:46 PM
>
> *To: *RE-wrenches;
>
> *Cc: *
>
> *Subject:*Re: [RE-wrenches] SMA SBxx-US-41 inverters and Tigo TS4A-O
> operation
>
>
>
> Does that go for not using Tigo with the SMA Core inverter as well?
>
>
>
> marco
>
> On Thursday, March 17, 2022, Glenn Burt <glenn.b...@glbcc.com> wrote:
>
> I attended some SMA training last week and we were clearly and
> emphatically told that they do not recomment any Tigo products be used with
> their inverters.
>
>
>
> -Glenn
>
> Sent from my 'smart'phone, so please excuse typos and spelling errors.
>
>
>
> ------ Original message------
>
> *From: *Jeremy Rodriguez
>
> *Date: *Thu, Mar 17, 2022 11:21 PM
>
> *To: *re-wrenches@lists.re-wrenches.org;
>
> *Cc: *
>
> *Subject:*[RE-wrenches] SMA SBxx-US-41 inverters and Tigo TS4A-O operation
>
>
>
> Hello,
>
> I normally do not install optimizing TS4s but we’ve got an upcoming
> project that will need it.
>
> SMA tech support was a bit uncertain that the latest -41 inverters did NOT
> require the CCA along with the Tigo Gateway, and that one could use the
> rooftop comm kit with the GIB gateway interface board.
>
>
>
> Can someone clarify if the CCA + Gateway are needed, or can I use the GIB
> to get the gateway communication established.
>
>
>
>
>
> Thanks in advance !
>
>
>
> Jeremy Rodriguez
>
> Solar Installation / Design Expert
>
> All Solar, Inc.
>
> 1453 M St
>
> Penrose Colorado 81240
>
>
>
> Sent by Jeremy's iPhone. Sorry for typos and shorthand.
>
>
_______________________________________________
List sponsored by Redwood Alliance

Pay optional member dues here: http://re-wrenches.org

List Address: RE-wrenches@lists.re-wrenches.org

Change listserver email address & settings:
http://lists.re-wrenches.org/options.cgi/re-wrenches-re-wrenches.org

There are two list archives for searching. When one doesn't work, try the other:
https://www.mail-archive.com/re-wrenches@lists.re-wrenches.org/
http://lists.re-wrenches.org/pipermail/re-wrenches-re-wrenches.org

List rules & etiquette:
http://www.re-wrenches.org/etiquette.htm

Check out or update participant bios:
http://www.members.re-wrenches.org

Reply via email to