Hi all, It works :-) In the first try I forgot to specify the constraints file.
For the sw part I use the "normal" functions (e.g., not the pr functions) and I use the "dow" command to load the (partial) bitstreams and the elf file. What is the status of the icap system on the ml605? If it is ready to use, how should the ecos .ecc file look like? Thanks, Ariane Ariane Keller wrote: > Hi all, > > I've tried the partial reconfiguration tool flow as discussed last > Friday. I think I got the steps right - at least it generated all the > bitfiles. I've downloaded the bitfile "config_1.bit" which should have > two add configurations in it. This worked fine. > However, when I try to connect to the microblaze > e.g. > xmd > connect mb mdm > > it does not recognize the version of the microblaze (see below). > > Do you have an idea what could have gone wrong? > > Thanks a lot! > Ariane > > ---------------------------------------------------------------- > XMD% WARNING: Processor Version 0x11 - UnSupported > 7.20.d, New > Features May Not Work > > > JTAG chain configuration > -------------------------------------------------- > Device ID Code IR Length Part Name > 1 0a001093 8 System_ACE_CF > 2 44250093 10 XC6VLX240T > > MicroBlaze Processor Configuration : > ------------------------------------- > Version............................0x11 - UnSupported > 7.20.d > Optimization.......................Performance > Interconnect.......................PLBv46 > MMU Type...........................No_MMU > No of PC Breakpoints...............1 > No of Read Addr/Data Watchpoints...0 > No of Write Addr/Data Watchpoints..0 > Instruction Cache Support..........on > Instruction Cache Base Address.....0xb0000000 > Instruction Cache High Address.....0xbfffffff > Data Cache Support.................on > Data Cache Base Address............0xb0000000 > Data Cache High Address............0xbfffffff > Exceptions Support................off > FPU Support.......................off > Hard Divider Support...............off > Hard Multiplier Support............on - (Mul32) > Barrel Shifter Support.............on > MSR clr/set Instruction Support....on > Compare Instruction Support........on > Data Cache Write-back Support......off > ERROR: MicroBlaze is under RESET. Check if the Reset input to > MicroBlaze and its Bus Interfaces are connected properly > UNABLE to STOP MicroBlaze > _______________________________________________ > Reconos-devel_lists.reconos.de mailing list > reconos-devel@lists.reconos.de > https://ml01.ispgateway.de/mailman/listinfo/reconos-devel_lists.reconos.de _______________________________________________ Reconos-devel_lists.reconos.de mailing list reconos-devel@lists.reconos.de https://ml01.ispgateway.de/mailman/listinfo/reconos-devel_lists.reconos.de