You are correct with your color ordering.(I believe this is EIA/TIA 568b
standard wiring) With Ethernet the important wires are 1,2,3 & 6. If
you need a crossover just exchange where the orange/white, orange,
green/white and green wires are on one end.(which would be 568a)
> -----Original Message-----
> From: David Fisher [SMTP:[EMAIL PROTECTED]]
> Sent: Monday, May 04, 1998 3:24 PM
> To: Rob Goodwin
> Subject: Re: Totally off topic: RJ45 fab
>
> If you can't find the colour code, then simply ensure that a
> given wire connects the same positions on each plug. As I'm
> not at the office right now, I can only take a stab at
> remembering the code. With the locking lever on the bottom,
> you should see, from left to right, white/orange, orange,
> green/white, blue, blue/white, green, brown/white, brown.
>
> I wouldn't bet the family farm on that order, however. If
> you could find a factory-made cable, you'd have no problem.
> Failing that, just connect pin 1 to pin 1, etc.
>
> Rob Goodwin wrote:
> >
> > Sorry this is off topic. Does anyone know where I can find the
> color order
> > for fabricating my own RJ45 patch cable. I've got the tools and
> parts.
> > Just don't know what order to put them in. Is there a site out
> there
> > somebody knows of?
> --
>
>
> David Fisher
> Chief Engineer
> Fisher Research Corporation
> Two Cairn Street
> Rochester, New York 14611-2476
> [EMAIL PROTECTED]
> 716 328 4230
> fax 328 1984
>
>
> --
> PLEASE read the Red Hat FAQ, Tips, Errata and the MAILING LIST
> ARCHIVES!
> http://www.redhat.com/RedHat-FAQ /RedHat-Errata /RedHat-Tips
> /mailing-lists
> To unsubscribe: mail [EMAIL PROTECTED] with
> "unsubscribe" as the Subject.
--
PLEASE read the Red Hat FAQ, Tips, Errata and the MAILING LIST ARCHIVES!
http://www.redhat.com/RedHat-FAQ /RedHat-Errata /RedHat-Tips /mailing-lists
To unsubscribe: mail [EMAIL PROTECTED] with
"unsubscribe" as the Subject.