Re-read what Larry (L7LJ) wrote.  They will work fine for a few months, then
they acting strange.

"w9mwq" <[EMAIL PROTECTED]> wrote:

> I have a Micor TLD1693 amp, designed for the 150 to 162 Mhz range, 
> and am told that the amp will not operate at the 146 Mhz range, told 
> that componets have to be changed.  Here is what I don't understand 
> about it, maybe someone can help expain it.  Into a Cushman serive 
> monitor, I'm getting 100 Watts out of the amp at both 146.925 and 
> 154.115 Mhz, keyed down the temperature is the same after a 5 min 
> keyup test, allowed to cool down for each test.  I see no spikes or 
> spurs at either frequency.  Granted this will be used on a repeater 
> and key down times can go much longer, but why would this amp not 
> operate at 2 meters, just cause Motorola says the specs are for 150 
> to 162.  I've seen amps go from 138 to 174 with no problems, just a 
> matter of tweaking.  So help me to understand what the difference 
> really is between the TLD1693 and the TLD1692 amps.  Thanks.
> 
> Mathew
> 
> 
> 
> 
> 
> 
>  