I am moving a 463/468 MHz Micor repeater to 444/449 MHz. I ordered new xtals from ICM and the receive xtal is OK. However I can't get the xmit xtal to pull onto freq. It will pull within 3 KHz above 444.350 MHz.
This isn't the first Micor I have changed rocks in myself. I've done several in the 450-470 MHz range without any problems and no realignment callbacks to the tower site. This isn't my "first time." I have a Micor test meter and used it to align the exciter and everything tuned as designed. I called ICM and they doubted it was their error and it must be my channel element since the frequency move was quite far. But for $30.00 they would "fix" the problem. Does anyone have any technical docs on the Micor channel elements and the require capacitor changes? The channel element is KXN1052A. I would rather replace the required cap with the correct value and get this repeater on the air instead of waiting another 3 weeks for ICM. I have read the Repeater-Builder webpage regarding Micor elements and it doesn't address the need to replace any components inside the element when moving from 463 to 444 MHz. 73's, Randy WB0VHB Yahoo! Groups Links <*> To visit your group on the web, go to: http://groups.yahoo.com/group/Repeater-Builder/ <*> To unsubscribe from this group, send an email to: [EMAIL PROTECTED] <*> Your use of Yahoo! Groups is subject to: http://docs.yahoo.com/info/terms/