enjoyacold807 wrote:
> Your basic GE Mastr II rack mount pwr supply (ref PL19D436272G1 Rev 
> A) was part of club WA8UXP's 2m GE MastrII (base) repeater (146.985 
> Mhz) until it started acting up (a few years ago).  Basically, the no 
> load voltage looked ok.  But, once the 100w PA kicked in the voltage 
> swings made a sunami look like a placid lake.  Ouch!!  It was then 
> replaced by Astron RS-35A.  Now, the club has three (3) choices for 
> the old fella being: boat anchor/scrap, try to fix, or hamfest sale 
> as is.  
> 
> But option 2, hmmm, if economically repairable, maybe we could put it 
> back where it belongs (w/ the repeater) and re-deploy the Astron.  
> Ah, life, so many choices, so little time.
> 

My first thought-those are ferro-resonant supplies. There's a cap across 
a special winding that provides some of the 'regulation'. If it went 
bad, I suspect it might do what your seeing...

Reply via email to