Did you try a hard reset? I had a problem where a port went "funny" and 
actually discovered that it was a macro causing the problem (after I'd sent 
it in for a new processor). The hard reset took care of it and I avoided the 
problem macro.

Chuck
WB2EDV



> Hello.  I have a Link Communications RLC-1 controller that has a bad
> repeater port.  The only thing wrong with that port is that the 2n7000 FET
> that keys the PTT is not getting a signal from the processor.  I checked 
> at
> pin 36 of the CPU and it only has .37 volts when it tries to key up the
> transmitter.  I have the link port setup for repeater, and I get 5 volts 
> and
> pin 35 of the CPU.  That port works fine.  I have narrowed this down to
> something wrong in the processor.  The processor is an MC68HC711E9.  I can
> get these through Mouser and Allied.  Does anyone know if these will work 
> or
> are they programmed from Link Communications for their controllers?
>