TP11 - TP19 should show +6 Volts when measured with a voltmeter on the DC setting. If not check that R8 and R9 are the correct value.
If that wasn't the problem, I'd try desoldering a pot and measure it with a meter out side the voter. On Sat, Nov 7, 2009 at 2:05 PM, Kevin Custer <kug...@kuggie.com> wrote: > > > John Transue wrote: > > Kevin, > > Each of the eight audio inputs to the voter is protected from DC by a > condenser. The audio out is also protected by a condenser. The audio > input to the RC-850 controller is also AC coupled. > > John > > > Have you looked with an oscilloscope to see if there is anything else > riding on the line? This behavior is not common to the LDG voter, so I'd > thing there is something weird happening as well. > > Kevin > > >