Joe,

Have you got a manual?  If not, it's available on the CATAUTO website.

You need to do a Dipswitch 7 reset to reset the password.  Per the manual:

"Switch 7 This switch is used to initialize the CAT-1000B. Set this switch
to ON. Cycle the
power OFF and back ON. During power-up, the memory will be flushed and
reloaded with
default values. The voice will say: "RESET DATA LOAD COMPLETED." Set switch
#7 to
the OFF position."

Don't forget, if you're programming by the Serial Port,  you have to set
Dipswitch 8 ON before programming and OFF again when complete. 

This switch is used to program a new unlock number. Set switch 8 to ON. The
voice
will say: "ENTER CONTROL." After the seven-digit unlock number is entered,
set switch
8 to OFF.
This switch is also used to activate the CAT-1000B computer interface. This
permits
programming of the CAT-1000B through the RS-232 serial port. Set dipswitch 8
to ON
and apply power to the CAT-1000B. After the power up message is complete,
the CAT-
1000B will automatically switch to the computer terminal programming mode.
This RS-
232 port is configured"

Mike


> -----Original Message-----
> From: Repeater-Builder@yahoogroups.com [mailto:Repeater-
> buil...@yahoogroups.com] On Behalf Of Joe
> Sent: Monday, December 07, 2009 6:02 PM
> To: Repeater-Builder@yahoogroups.com
> Subject: [Repeater-Builder] Programming a CAT1000
> 
> I found my DOS disk program, but can't find my notes on how to use the
> program.  Anyone have this information?  Also, it looks like someone
> changed the default password of "cat1000", does anyone know if it can
> be
> reset?
> 
> I'm working on a repeater for a club and I'm trying to get it off my
> bench, any help is appreciated!
> 
> 73, Joe, K1ike
> 
> 
> ------------------------------------
> 
> 
> 
> Yahoo! Groups Links
> 
> 
> 


Reply via email to