Dear All, I am carying out Rietveld refinement of a deformed polycrystalline sample. WH plot shows anisotropic broadening of the profile. If I incorporate Stephens Model in GSAS, it improves the quality of the fit.
Now my question is: In this case if I use the refined parameters (of Stephens model)to draw the 3D-anisotropic strain field within the sample, does it carry any physical meaning! Thanking you. With best regards, Apu