Just to follow up, this issue was patched on 2016-01-13. Thanks guys! On Tue, Jan 12, 2016 at 10:34 PM, Matt Calder <[email protected]> wrote:
> Starting on Jan 6th, I started getting this error when creating new > measurements. > > "Your selection of probes contains at least one probe that is unavailable. > Error 104." > > These measurements had been running with no issues for the last year. I > tried checking through the API that all probe's status' are Connected and > are Public but it doesn't seem to make a difference. I am specifying a > list of specific probes to be used which is needed for the specific > experiment. Small number of probes like 1, 2, or 3 usually work. Larger > numbers like 10 - 75, work occasionally. 300 - 400 probes per measurement > never seem to work. > > Appreciate any help. > > Matt >