Salut,

Folosind lm_sensors incerc sa ignor niste alarme false de sensori (sau sa le schimb valorile minime/maxime).
Am output-ul asta:

# sensors
sch5027-i2c-0-2e
Adapter: SMBus I801 adapter at 3000
in0:         +4.51 V  (min =  +0.00 V, max =  +6.64 V)
in1:         +1.12 V  (min =  +0.00 V, max =  +2.99 V)
in2:         +3.31 V  (min =  +0.00 V, max =  +4.38 V)
in3:         +0.34 V  (min =  +0.00 V, max =  +1.49 V)
in4:         +1.21 V  (min =  +0.00 V, max =  +1.49 V)
in5:         +3.28 V  (min =  +0.00 V, max =  +4.38 V)
in6:         +3.12 V  (min =  +0.00 V, max =  +4.38 V)
fan1:          0 RPM  (min = 2400 RPM)  ALARM
fan2:        747 RPM  (min = 2400 RPM)  ALARM
fan3:       2917 RPM  (min = 2400 RPM)
fan4:       2954 RPM  (min = 2400 RPM)
fan5:       1500 RPM  (min = 2400 RPM)  ALARM
fan6:          0 RPM  (min = 2400 RPM)  ALARM
temp1:       -55.0°C  (low  = -127.0°C, high = +127.0°C)
temp2:       +36.2°C  (low  = -127.0°C, high = +127.0°C)
temp3:       +28.0°C  (low  = -127.0°C, high = +127.0°C)

# sensors --bus-list
bus "i2c-0" "SMBus I801 adapter at 3000"

# cat /etc/sysconfig/lm_sensors
MODULE_0=i2c-i801
MODULE_1=dme1737
MODULE_2=coretemp

In /etc/sensors3.conf am:
chip "dme1737-*"
ignore fan1
ignore fan6

Am incercat si cu chip "i2c-*" dar dupa 'sensors -s' nu s-a schimbat nimic. Gresesc eu undeva? Nu ar trebui sa dispara alarmele daca ignor sau modific valori in fisierul de configurare?


Toate bune,
--
Catalin Bucur      mailto:[EMAIL PROTECTED]
NOC @ Genius Network SRL - Galati - Romania

_______________________________________________
RLUG mailing list
[email protected]
http://lists.lug.ro/mailman/listinfo/rlug

Raspunde prin e-mail lui