Salut, Am un server vechi HP cu un RAID5 cu un disk defect. L-am schimbat fizic cu unul nou, dar array-ul nu vrea să se refacă. Am instalat hpacucli și pot să văd starea array-ului și a discurilor:
[root@Tassadar adrianp]# hpacucli HP Array Configuration Utility CLI 9.20.9.0 Detecting Controllers...Done. Type "help" for a list of supported commands. Type "exit" to close the console. => ctrl slot=0 logicaldrive all show status logicaldrive 1 (136.7 GB, RAID 1): OK logicaldrive 2 (1.4 TB, RAID 5): Interim Recovery Mode => controller slot=0 show config Smart Array P410i in Slot 0 (Embedded) (sn: 500143800891C3B0) array A (SAS, Unused Space: 0 MB) logicaldrive 1 (136.7 GB, RAID 1, OK) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 146 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 146 GB, OK) array B (SAS, Unused Space: 0 MB) logicaldrive 2 (1.4 TB, RAID 5, Interim Recovery Mode) physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 300 GB, Predictive Failure) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 300 GB, OK) physicaldrive 2I:1:5 (port 2I:box 1:bay 5, SAS, 300 GB, Failed) physicaldrive 2I:1:6 (port 2I:box 1:bay 6, SAS, 300 GB, OK) physicaldrive 2I:1:7 (port 2I:box 1:bay 7, SAS, 300 GB, OK) physicaldrive 2I:1:8 (port 2I:box 1:bay 8, SAS, 300 GB, OK) SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 250 (WWID: 500143800891C3BF) Am încercat să scot discul 1:5, dar nu mă lasă: => controller slot=0 array B remove drives=1:5 Error: This operation is not supported with the current configuration. Use the "show" command on devices to show additional details about the configuration. Reason: Array is transforming Aveți o sugestie ce ar trebui să-l fac să recitească discul din 1:5 și să facă rebuild? Mulțumesc. _______________________________________________ RLUG mailing list RLUG@lists.lug.ro http://lists.lug.ro/mailman/listinfo/rlug_lists.lug.ro