switch cu management care isi schimba modalitatea de comutatie
(cut-through, store and forward, etc) adaptandu-se la trafic


On Wed, 2005-07-27 at 22:13 +0300, Tarhon-Onu Victor wrote:
> On Wed, 27 Jul 2005, Giany wrote:
> 
> > Jul 25 18:45:45 slider kernel: eth0: link down
> > Jul 25 18:46:01 slider kernel: eth0: link up, 100Mbps, full-duplex, lpa
> > 0x41E1
> 
>       Poate fi:
>       - un cablu defect;
>       - conector defect in placa sau switch;
>       - transceiver prin copaci in placa (sau switch);
>       - sau, cum spune prietenul omului, google, p0rnblema de driver 
> (ai 8139too, eh? aia e placa de retea?).
> 


--- 
Detalii despre listele noastre de mail: http://www.lug.ro/


Raspunde prin e-mail lui