Hi, > Compression for me is working with packet lengths less than <1500 > bytes > > attached is the text with out of my program. > > Can you please advise me regarding this..?
At the end of the output you sent me, there are the following lines : fragment error in outer IP header error while compressing with the profile, using uncompressed profile uncompressed profile not found, giving up That means that your 1500-byte IP packet is an IP fragment. The ROHC protocol and therefore the ROHC library do not support compression of IP fragments with the IP-only, UDP or RTP profiles. Only the Uncompressed profile supports IP fragments. The last line show that the Uncompressed profile is disabled, so compression of your 1500-byte IP fragment is impossible. To fix the problem, enable the Uncompressed profile or do not compress IP fragments. Didier Barvaux Viveris Technologies _______________________________________________ Mailing list: https://launchpad.net/~rohc Post to : [email protected] Unsubscribe : https://launchpad.net/~rohc More help : https://help.launchpad.net/ListHelp