when rm_ping client fails to run again correctly the data base need clean up.
-----------------------------------------------------------------------------

                 Key: SANDESHA2C-34
                 URL: https://issues.apache.org/jira/browse/SANDESHA2C-34
             Project: Sandesha2/C
          Issue Type: Bug
         Environment: Linux+MySQL
            Reporter: Manjula Peiris
            Priority: Critical


In rm_ping clinet the user does not create a SequenceKey . so when creating 
InternalSequenceId it uses only the endpoint address. So if one invocation 
fails  during the second invocation the same internalsequenceId is used. This 
can be solved by providing a Sequencekey as done in other sandesha2/c samples.

-- 