On 26/12/2019 17:52, Thierry HUCAHRD wrote:
Hi Till
We have worked with more than 10 different brands of scanners.
The eSCL backend integrated in sane has already solved the problem.
The size of the calculated image is wrong compared to the received one.


Thierry, you are the winner for now. Your "escl" backend did not auto-discover the network presence of my device via DNS-SD (Alexander's "airscan" backend does), but manually entering the data into the escl.conf file I am able to scan! And it works both via network and via USB with ippusbxd.

For accessing via the network I enter:

----------
[device]

model DeskJet 2540
type http
ip 192.168.43.161
port 8080
----------

and for accessing via USB with ippusbxd I enter:

----------
[device]

model USB via ippusbxd
type http
ip 127.0.0.1
port 60000
----------

Thank for your great work, Thierry.

   Till

Reply via email to