Hi, On Wed, Jan 14, 2026 at 8:02 PM William Gaylord <[email protected]> wrote:
> So I have been using the mostly working driver for the G3110, and have > found that if I use the highest available resolution it will run the scan > head right into the end of the scanner just randomly before it even starts > scanning. Anyone have any suggestions? > > Additionally, since I have the scanner up and running I will be willing to > work on trying to debug this (so i can use it) but I sort of need help on > how to get started with building SANE from source. Although this might be a > better question to ask the Debian maintainer since I am running Debian. > Can you let us know which version of SANE you are currently running? scanimage -V is one way to know. Building on Debian is straightforward. 1) Get the build dependencies: sudo apt build-dep libsane1 2) Clone the backends repo: git clone https://gitlab.com/sane-project/backends.git 3) Build: cd backends ./autogen.sh ./configure ./make ./make install This will install to /usr/local, but you can use --prefix={dir} to set a different target, perhaps in your home directory. That's what I do. Cheers, Ralph