I can't scan with Epson Rx500 Multifunction scanner. On my Mandrake 10.0 after adding vendor and product ID (usb 0x4b8 0x0807) in 'epson.conf' it is recognized but when I try scanimage it gives me: scanimage: sane_start: Operation not supported
I have tried: # SANE_DEBUG_EPSON=128 scanimage This is the output: [sanei_debug] Setting debug level of epson to 128. [epson] sane_init: sane-backends 1.0.14 [epson] sane_init, ># epson.conf< [epson] sane_init, >#< [epson] sane_init, ># here are some examples for how to configure the EPSON backend< [epson] sane_init, >#< [epson] sane_init, ># SCSI scanner:< [epson] sane_init, ># scsi EPSON< [epson] sane_init, >#< [epson] sane_init, ># Parallel port scanner:< [epson] sane_init, >#pio 0x278< [epson] sane_init, >#pio 0x378< [epson] sane_init, >#pio 0x3BC< [epson] sane_init, >#< [epson] sane_init, ># USB scanner:< [epson] sane_init, ># There are two different methods of configuring a USB scanner: libusb and the kernel module< [epson] sane_init, ># For any system with libusb support (which is pretty much any recent Linux distribution) the< [epson] sane_init, ># following line is sufficient. This however assumes that the connected scanner (or to be more< [epson] sane_init, ># accurate, it's device ID) is known to the backend.< [epson] sane_init, >usb< [epson] attach_one_usb() [epson] SANE Epson Backend v0.2.41 - 2004-02-01 [epson] attach(, 3) [epson] attach: opening [epson] attach_one_usb(libusb:003:003) [epson] SANE Epson Backend v0.2.41 - 2004-02-01 [epson] attach(libusb:003:003, 3) [epson] attach: opening libusb:003:003 [epson] Found valid EPSON scanner: 0x4b8/0x807 (vendorID/productID) [epson] reset() [epson] send buf, size = 2 [epson] buf[0] 1b . [epson] buf[1] 40 @ [epson] receive buf, expected = 1, got = 1 [epson] buf[0] 06 . [epson] get_identity_information() [epson] send buf, size = 2 [epson] buf[0] 1b . [epson] buf[1] 49 I [epson] receive buf, expected = 4, got = 4 [epson] buf[0] 02 . [epson] buf[1] 12 . [epson] buf[2] 13 . [epson] buf[3] 00 . [epson] code 02 [epson] status 12 [epson] count 19 [epson] receive buf, expected = 19, got = 19 [epson] buf[0] 44 D [epson] buf[1] 38 8 [epson] buf[2] 52 R [epson] buf[3] 64 d [epson] buf[4] 00 . [epson] buf[5] 52 R [epson] buf[6] 2c , [epson] buf[7] 01 . [epson] buf[8] 52 R [epson] buf[9] b0 . [epson] buf[10] 04 . [epson] buf[11] 52 R [epson] buf[12] 60 ` [epson] buf[13] 09 . [epson] buf[14] 41 A [epson] buf[15] b0 . [epson] buf[16] 4f O [epson] buf[17] b0 . [epson] buf[18] 6d m [epson] type D 0x44 [epson] level 8 0x38 [epson] option equipment is installed [epson] resolution (dpi): 100 [epson] resolution (dpi): 300 [epson] resolution (dpi): 1200 [epson] resolution (dpi): 2400 [epson] maximum scan area: x 20400 y 28080 [epson] fbf tlx 0.000000 tly 0.000000 brx 215.899994 bry 297.179993 [mm] [epson] get_identity2_information() [epson] send buf, size = 2 [epson] buf[0] 1b . [epson] buf[1] 69 i [epson] receive buf, expected = 4, got = 4 [epson] buf[0] 02 . [epson] buf[1] 12 . [epson] buf[2] 9c . [epson] buf[3] 00 . [epson] receive buf, expected = 156, got = 156 [epson] buf[0] 60 ` [epson] buf[1] 09 . [epson] buf[2] d5 . [epson] buf[3] 00 . [epson] buf[4] 00 . [epson] buf[5] 00 . [epson] buf[6] 00 . [epson] buf[7] 00 . [epson] buf[8] 00 . [epson] buf[9] 00 . [epson] buf[10] 00 . [epson] buf[11] 00 . [epson] buf[12] 00 . [epson] buf[13] 00 . [epson] buf[14] 32 2 [epson] buf[15] 00 . [epson] buf[16] 48 H [epson] buf[17] 00 . [epson] buf[18] 4b K [epson] buf[19] 00 . [epson] buf[20] 60 ` [epson] buf[21] 00 . [epson] buf[22] 64 d [epson] buf[23] 00 . [epson] buf[24] 96 . [epson] buf[25] 00 . [epson] buf[26] c8 . [epson] buf[27] 00 . [epson] buf[28] f0 . [epson] buf[29] 00 . [epson] buf[30] 0a . [epson] buf[31] 01 . [epson] buf[32] 2c , [epson] buf[33] 01 . [epson] buf[34] 5e ^ [epson] buf[35] 01 . [epson] buf[36] 68 h [epson] buf[37] 01 . [epson] buf[38] 90 . [epson] buf[39] 01 . [epson] buf[40] f4 . [epson] buf[41] 01 . [epson] buf[42] 58 X [epson] buf[43] 02 . [epson] buf[44] bc . [epson] buf[45] 02 . [epson] buf[46] d0 . [epson] buf[47] 02 . [epson] buf[48] 20 [epson] buf[49] 03 . [epson] buf[50] 84 . [epson] buf[51] 03 . [epson] buf[52] e8 . [epson] buf[53] 03 . [epson] buf[54] 4c L [epson] buf[55] 04 . [epson] buf[56] b0 . [epson] buf[57] 04 . [epson] buf[58] 14 . [epson] buf[59] 05 . [epson] buf[60] 78 x [epson] buf[61] 05 . [epson] buf[62] dc . [epson] buf[63] 05 . [epson] buf[64] 40 @ [epson] buf[65] 06 . [epson] buf[66] a4 . [epson] buf[67] 06 . [epson] buf[68] 08 . [epson] buf[69] 07 . [epson] buf[70] 6c l [epson] buf[71] 07 . [epson] buf[72] d0 . [epson] buf[73] 07 . [epson] buf[74] 34 4 [epson] buf[75] 08 . [epson] buf[76] 98 . [epson] buf[77] 08 . [epson] buf[78] fc . [epson] buf[79] 08 . [epson] buf[80] 60 ` [epson] buf[81] 09 . [epson] buf[82] 00 . [epson] buf[83] 00 . [epson] buf[84] 32 2 [epson] buf[85] 00 . [epson] buf[86] 48 H [epson] buf[87] 00 . [epson] buf[88] 4b K [epson] buf[89] 00 . [epson] buf[90] 60 ` [epson] buf[91] 00 . [epson] buf[92] 64 d [epson] buf[93] 00 . [epson] buf[94] 96 . [epson] buf[95] 00 . [epson] buf[96] c8 . [epson] buf[97] 00 . [epson] buf[98] f0 . [epson] buf[99] 00 . [epson] buf[100] 0a . [epson] buf[101] 01 . [epson] buf[102] 2c , [epson] buf[103] 01 . [epson] buf[104] 5e ^ [epson] buf[105] 01 . [epson] buf[106] 68 h [epson] buf[107] 01 . [epson] buf[108] 90 . [epson] buf[109] 01 . [epson] buf[110] f4 . [epson] buf[111] 01 . [epson] buf[112] 58 X [epson] buf[113] 02 . [epson] buf[114] bc . [epson] buf[115] 02 . [epson] buf[116] d0 . [epson] buf[117] 02 . [epson] buf[118] 20 [epson] buf[119] 03 . [epson] buf[120] 84 . [epson] buf[121] 03 . [epson] buf[122] e8 . [epson] buf[123] 03 . [epson] buf[124] 4c L [epson] buf[125] 04 . [epson] buf[126] b0 . [epson] buf[127] 04 . [epson] buf[128] 14 . [epson] buf[129] 05 . [epson] buf[130] 78 x [epson] buf[131] 05 . [epson] buf[132] dc . [epson] buf[133] 05 . [epson] buf[134] 40 @ [epson] buf[135] 06 . [epson] buf[136] a4 . [epson] buf[137] 06 . [epson] buf[138] 08 . [epson] buf[139] 07 . [epson] buf[140] 6c l [epson] buf[141] 07 . [epson] buf[142] d0 . [epson] buf[143] 07 . [epson] buf[144] 34 4 [epson] buf[145] 08 . [epson] buf[146] 98 . [epson] buf[147] 08 . [epson] buf[148] fc . [epson] buf[149] 08 . [epson] buf[150] 60 ` [epson] buf[151] 09 . [epson] buf[152] c0 . [epson] buf[153] 12 . [epson] buf[154] 00 . [epson] buf[155] 00 . [epson] send buf, size = 2 [epson] buf[0] 1b . [epson] buf[1] 44 D [epson] receive buf, expected = 1, got = 1 [epson] buf[0] 06 . [epson] send buf, size = 1 [epson] buf[0] 10 . [epson] receive buf, expected = 1, got = 1 [epson] buf[0] 06 . [epson] Max. supported color depth = 16 [epson] request_focus_position() [epson] Disabling 'Set Focus' support [epson] send buf, size = 2 [epson] buf[0] 1b . [epson] buf[1] 66 f [epson] receive buf, expected = 4, got = 4 [epson] buf[0] 02 . [epson] buf[1] 12 . [epson] buf[2] 2a * [epson] buf[3] 00 . [epson] code 02 [epson] status 12 [epson] count 42 [epson] receive buf, expected = 42, got = 42 [epson] buf[0] 05 . [epson] buf[1] 00 . [epson] buf[2] 00 . [epson] buf[3] 00 . [epson] buf[4] 00 . [epson] buf[5] 00 . [epson] buf[6] 80 . [epson] buf[7] d0 . [epson] buf[8] 11 . [epson] buf[9] 50 P [epson] buf[10] 55 U [epson] buf[11] c0 . [epson] buf[12] b0 . [epson] buf[13] 4f O [epson] buf[14] b0 . [epson] buf[15] 6d m [epson] buf[16] 00 . [epson] buf[17] 00 . [epson] buf[18] 00 . [epson] buf[19] 00 . [epson] buf[20] 00 . [epson] buf[21] 00 . [epson] buf[22] 00 . [epson] buf[23] 00 . [epson] buf[24] 00 . [epson] buf[25] 00 . [epson] buf[26] 52 R [epson] buf[27] 58 X [epson] buf[28] 35 5 [epson] buf[29] 30 0 [epson] buf[30] 30 0 [epson] buf[31] 20 [epson] buf[32] 20 [epson] buf[33] 20 [epson] buf[34] 20 [epson] buf[35] 20 [epson] buf[36] 20 [epson] buf[37] 20 [epson] buf[38] 20 [epson] buf[39] 20 [epson] buf[40] 20 [epson] buf[41] 20 [epson] TPU detected [epson] tpu tlx 0.000000 tly 0.000000 brx 48.259995 bry 231.139999 [mm] [epson] scanner model: RX500 [epson] close_scanner(fd = 0) [epson] sane_init, ># For libusb support for unknown scanners use the following command< [epson] sane_init, ># usb <product ID> <device ID>< [epson] sane_init, ># e.g.:< [epson] sane_init, >usb 0x4b8 0x0807< [epson] attach_one_usb(libusb:003:003) [epson] SANE Epson Backend v0.2.41 - 2004-02-01 [epson] attach(libusb:003:003, 3) [epson] sane_init, ># And for the scanner module, use the following configuration:< [epson] sane_init, >#usb /dev/usbscanner0< [epson] sane_init, >#usb /dev/usb/scanner0< [epson] sane_get_devices() [epson] sane_open(libusb:003:003) [epson] init_options() [epson] open_scanner() [epson] setvalue(option = 38, value = 0xbfff6578 [epson] set = 215.899994 [epson] setvalue(option = 39, value = 0xbfff6578 [epson] set = 297.179993 [epson] sane_start() [epson] open_scanner() [epson] scanner is already open: fd = 0 [epson] You may have to power off your TPU [epson] Also you may have to restart the Sane frontend.[epson] close_scanner(fd = 0) It all works fine on Windoez :-( Printing works fine with StylusPhoto925 driver PLEASE HELP ME!!! WHAT CAN I DO??? THANKS. -- metgorna <metgornanos...@inwind.it>