Hi, On Tuesday 16 March 2004 15:16, Christopher Marshall wrote: [SNIPSNAP] > I am curious as to what the problem was, though, that was fixed.
The problem was the lamp-calibration, which has not been correctly done in the previous versions. Thanx to monty for the patch to make it work... Ciao, Gerhard > > Chris Marshall > > --- Gerhard Jaeger <[email protected]> wrote: > > Hi, > > > > On Monday 15 March 2004 21:11, Christopher Marshall wrote: > > [SNIPSNAP] > > > > > > I'd be very surprised if that was true. The Canon Lide 80 uses the > > > > Genesys GL841 chips as far as I know. It's not supported by SANE. > > > > > > I am sorry, I keep making that mistake. I am using the CanoScan LiDE > > > 30 with the plustek backend. > > > > That's what I expected ;-) > > > > > > Please show us the output of "sane-find-scanner -v -v", > > > > "scanimage --version" and "scanimage -L". > > > > > > "scanimage --version" reports: > > > > > > scanimage (sane-backends) 1.0.11; backend version 1.0.11 > > > > hmmm, too old. Please use the latest CVS version - the stripe-problem > > should be solved. Probably also 1.0.13 will solve the problem, although > > it contains a bug in the calibration, which affects some LiDE20/30 > > devices... > > > > Ciao, > > Gerhard > > > > > > -- > > sane-devel mailing list: [email protected] > > http://lists.alioth.debian.org/mailman/listinfo/sane-devel > > Unsubscribe: Send mail with subject "unsubscribe your_password" > > to [email protected] > > __________________________________ > Do you Yahoo!? > Yahoo! Mail - More reliable, more storage, less spam > http://mail.yahoo.com