SANE-Backends-1.0.13 ---------------------------------- SCSI storage controller: LSI Logic / Symbios Logic 53c875 (rev 04) (Works well with SANE-Backends-1.0.12, cdrecord, DAT-Tape, disks)
The scanner has two interfaces SCSI(attached) and USB(unplugged). sane-find-scanner -q found SCSI processor "EPSON Perfection1640 1.06" at /dev/sg2 found USB scanner (vendor=0x067b, product=0x2303) at libusb:003:003 Bug : Scanner found on unused interface too. Wish: Device independent reporting format, would make writing scanner scripts simpler. e.g. Found Scanner "EPSON Perfection1640 1.06" (vendor=0x067b, product=0x2303) \ SCSI epson:/dev/sg2 Found Scanner "EPSON Perfection1640 1.06" (vendor=0x067b, product=0x2303) \ USB epson:libusb:003:003 ---------------------------------- scanimage -L No scanners were identified. If you were expecting something different, check that the scanner is plugged in, turned on and detected by the sane-find-scanner tool (if appropriate). Please read the documentation which came with this software (README, FAQ, manpages). but scanimage -d epson:/dev/sg2 --test works, the scanner does something. scanimage -d epson:/dev/sg2 --resolution 100 returns scanimage: sane_start: Error during device I/O but after a export SANEI_DEBUG_SANEI_SCSI=128 scanimage -d epson:/dev/sg2 --resolution 100 P4 # SANE data follows 848 1169 ... works, puts out data. scanimage -L device `epson:/dev/sg2' is a Epson Perfection1640 flatbed scanner now works too. Seems the bug has to do with debugging. ---------------------------------- Karl-Heinz I saw the fromfeed was alreay fixed in 1.0.13. -- Regards Klaus