Hi Christoph, would you please send me a logfile like described in the manpage sane-microtek2? I can see then which commands are transfered to the scanner, hopefully I'll get a hint why the lamp is switched on again.
Karsten > Hi Karsten, > > it seems not to resolve this problem. I've changed the microtec2-files > after > building on bth machines, the server and the client (which might be not > nessesary because of net-scanning). With click on the "toggle-lamp"-button > the lamp switches of, but when I'm scanning (preview and final) the lamp > is > allways on. > > Christoph > > Am Montag, 26. April 2004 21:35 schrieb Karsten Festag: > > Hi Christoph, > > > > I'm having a bad conscience because you asked me this half a year ago... > > sorry. > > > > please try the following modification: > > > > in microtek2.c around line 5330 you'll find the following piece of code: > > > > if ( ms->lightlid35 ) > > { > > md->status.flamp &= ~MD_FLAMP_ON; > > md->status.tlamp |= MD_TLAMP_ON; > > } > > > > please comment out the second line so it looks like > > > > if ( ms->lightlid35 ) > > { > > md->status.flamp &= ~MD_FLAMP_ON; > > /* md->status.tlamp |= MD_TLAMP_ON; */ > > } > > > > and recompile sane-backends. In theory this second line would switch on > > only the transparency lamp but maybe it also controls the flatbed lamp. > > > > Please let me know about the results! > > > > Karsten > -- NEU : GMX Internet.FreeDSL Ab sofort DSL-Tarif ohne Grundgebühr: http://www.gmx.net/dsl