Pierre Willenbrock schrieb: > Bulk access differs in all cases between gl646 and gl841. > genesys_com.diff.gz moves the bulk functions into the chip specific > source files. I also moved the last two occurences of send_slope_table > in genesys.c to genesys_gl646.c and genesys_gl841.c, since the gl841 > uses 5 tables instead of 2(and therefore should initialize them).
Sorry, i missed one sanei_genesys_bulk_read_data. Corrected patch attached. Regards, Pierre -------------- next part -------------- A non-text attachment was scrubbed... Name: genesys_com.diff.gz Type: application/x-gzip Size: 6300 bytes Desc: not available Url : http://lists.alioth.debian.org/pipermail/sane-devel/attachments/20050805/3b32ccaf/genesys_com.diff-0001.bin From p...@smedley.info Sat Aug 6 08:48:45 2005 From: p...@smedley.info (Paul Smedley) Date: Sat Aug 6 08:49:22 2005 Subject: [sane-devel] Epson Perfection 2400 Problems Message-ID: <42f4796d.7010...@smedley.info> Hi All, Wondering if anyone can suggestion possible reasons for an Epson Perfection 2400 not working on OS/2. Code is built from latest CVS, and many other scanners that use the Snapscan backend are reported to work. Epson Perfection 2400 seems to have problems uploading the firmware - the log ends with: [snapscan] usb_request_sense: usb command error: Error during device I/O [snapscan] usb_request_sense: usb command error: Error during device I/O [snapscan] sane_snapscan_open: download_firmware command failed: Error during device I/O scanimage: open of device snapscan:usbcalls:1 failed: Error during device I/O Full log is at http://smedley.info/epson2400debugoutput.zip Any ideas appreciated. Cheers, Paul.