=========================================== == Neuer Eintrag ===========================================
------------------------------------------- -- Formular: 'adddev' ------------------------------------------- 1. Your email address: 'alek...@nedorezov.com' 2. Manufacturer (e.g. "Mustek"): 'Genius' 3. Model name (e.g. ScanExpress 1200UB): 'ColorPage Slim 1200' 4. Bus type: 'USB' 5. Vendor id (e.g. 0x001): '0x0458' 6. Product id (e.g. 0x0002): '0x201E' 7. Chipset (e.g. lm9831): 'gt6816' 8. Comments (e.g. similar to Mustek 1234): 'Hello, Works with following modifications on gtxx_devices.c Scanner looks like similar as Plustek OpticSlim 2400 static GT68xx_Model genius_colorpageslim_1200_model = { "genius-colorpageslim-1200", /* Name */ "Genius", /* Device vendor string */ "ColorPage Slim 1200", /* Device model name */ "Cis3r5b1.fw", /* Name of the firmware file */ SANE_FALSE, /* Dynamic allocation flag */ &mustek_gt6816_command_set, /* Command set used by this scanner */ 1200, /* maximum optical sensor resolution */ 2400, /* maximum motor resolution */ 1200, /* base x-res used to calculate geometry */ 1200, /* base y-res used to calculate geometry */ 1200, /* if ydpi is equal or higher, disable backtracking */ SANE_FALSE, /* Use base_ydpi for all resolutions */ {1200, 600, 300, 150, 100, 50, 0}, /* possible x-resolutions */ {2400,1200, 600, 300, 150, 100, 50, 0}, /* possible y-resolutions */ {16, 12, 8, 0}, /* possible depths in gray mode */ {16, 12, 8, 0}, /* possible depths in color mode */ SANE_FIX (0.5), /* Start of scan area in mm (x) */ SANE_FIX (8.0), /* Start of scan area in mm (y) */ SANE_FIX (218.0), /* Size of scan area in mm (x) */ SANE_FIX (299.0), /* Size of scan area in mm (y) */ SANE_FIX (0.0), /* Start of white strip in mm (y) */ SANE_FIX (9.5), /* Start of black mark in mm (x) */ SANE_FIX (0.0), /* Start of scan area in TA mode in mm (x) */ SANE_FIX (0.0), /* Start of scan area in TA mode in mm (y) */ SANE_FIX (0.0), /* Size of scan area in TA mode in mm (x) */ SANE_FIX (0.0), /* Size of scan area in TA mode in mm (y) */ SANE_FIX (0.0), /* Start of white strip in TA mode in mm (y) */ 0, 0, 0, /* RGB CCD Line-distance correction in pixel */ 0, /* CCD distcance for CCD with 6 lines) */ COLOR_ORDER_RGB, /* Order of the CCD/CIS colors */ {0x19, 0x1a, 0x18, 0x14, 0x18, 0x12}, /* Default offset/gain */ {0x548, 0x513, 0x48d}, /* Default exposure parameters */ SANE_FIX (1.5), /* Default gamma value */ SANE_TRUE, /* Is this a CIS scanner? */ GT68XX_FLAG_ALWAYS_LINEMODE | GT68XX_FLAG_SE_2400 }; ' 9. Data (e.g. sane-find-scanner -v -v): '<device descriptor of 0x0458/0x201e at 001:007 (Genius CP-Slim 1200)> bLength 18 bDescriptorType 1 bcdUSB 1.10 bDeviceClass 0 bDeviceSubClass 0 bDeviceProtocol 0 bMaxPacketSize0 64 idVendor 0x0458 idProduct 0x201E bcdDevice 5.01 iManufacturer 0 () iProduct 1 (Genius CP-Slim 1200) iSerialNumber 0 () bNumConfigurations 1 <configuration 0> bLength 9 bDescriptorType 2 wTotalLength 32 bNumInterfaces 1 bConfigurationValue 1 iConfiguration 0 () bmAttributes 160 (Remote Wakeup) MaxPower 500 mA <interface 0> <altsetting 0> bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 2 bInterfaceClass 255 bInterfaceSubClass 255 bInterfaceProtocol 255 iInterface 0 () <endpoint 0> bLength 7 bDescriptorType 5 bEndpointAddress 0x81 (in 0x01) bmAttributes 2 (bulk) wMaxPacketSize 64 bInterval 0 ms bRefresh 0 bSynchAddress 0 <endpoint 1> bLength 7 bDescriptorType 5 bEndpointAddress 0x02 (out 0x02) bmAttributes 2 (bulk) wMaxPacketSize 64 bInterval 0 ms bRefresh 0 bSynchAddress 0 <trying to find out which USB chip is used> checking for GT-6801 ... this is not a GT-6801 (bDeviceClass = 0) checking for GT-6816 ... <This USB chip looks like a GT-6816 (result from sane-backends 1.0.18)> found USB scanner (vendor=0x0458, product=0x201e [Genius CP-Slim 1200], chip=GT-6816) at libusb:001:007 '