Hi Allan, I have now disabled agfafocus and enabled microtek. scanimage -L works now. This is great. Thank you!
Unfortunately, I still can not scan a page. I get the following error message. scanimage: sane_start: Error during device I/O I have attached the output of scanimage at the end of this e-mail. I have switched the debugging on for sanei_scsi and microtek. I guess there might be a problem with the commands that are sent to the device. Suggestions highly appreciated. Werner On 22.07.2011, at 12:51, m. allan noah wrote: > Try changing /etc/sane.d/dll.conf. Disable agfafocus and make sure > microtek is enabled. > > allan $ scanimage > Desktop/test.pnm [sanei_debug] Setting debug level of microtek to 128. [microtek] sane_init: MICROTEK says hello! (v0.13.1) [microtek] sane_init: config-> # Uncomment following line to disable "real calibration" routines... [microtek] sane_init: config-> #norealcal [microtek] sane_init: config-> # Uncomment following line to disable "clever precalibration" routines... [microtek] sane_init: config-> #noprecal [microtek] sane_init: config-> # Using "norealcal" will revert backend to pre-0.11.0 calibration code. [microtek] sane_init: config-> scsi * * Scanner [microtek] attach_scanner: <019bc800000000172dcdf573> [microtek] attach_scanner: opening <019bc800000000172dcdf573> [sanei_debug] Setting debug level of sanei_scsi to 255. [microtek] attach_scanner: sending INQUIRY [sanei_scsi] cmd2: cmd_size:6 src_size:0 dst_size:96 isWrite:0 [sanei_scsi] isRead dst_size:96 [sanei_scsi] Executing command [sanei_scsi] ExecuteTaskSync OK Transferred 96 bytes [microtek] id_microtek... [microtek] [microtek] [microtek] [microtek] ========== Congratulations! ========== [microtek] Your scanner appears to be supported [microtek] by the microtek backend. However, it [microtek] has never been tried before, and some [microtek] parameters are bound to be wrong. [microtek] [microtek] Please send the scanner inquiry log in [microtek] its entirety to mtek-bugs at mir.com and [microtek] include a description of the scanner, [microtek] including the base optical resolution. [microtek] [microtek] You'll find complete instructions for [microtek] submitting an error/debug log in the [microtek] 'sane-microtek' man-page. [microtek] [microtek] [microtek] [microtek] === SANE/Microtek backend v0.13.1 === [microtek] ========== Scanner Inquiry Block ========mm [microtek] 06 00 01 01 5b 00 00 00 41 47 46 41 20 20 20 20 [microtek] 44 55 4f 53 43 41 4e 20 20 20 20 20 20 20 20 20 [microtek] 32 2e 33 30 53 43 53 49 20 46 57 20 56 33 2e 36 [microtek] 20 43 54 4c 35 33 38 30 03 4f 8c c5 06 ee 5d 43 [microtek] 01 03 47 00 00 83 00 01 0e 4a 07 05 00 00 00 00 [microtek] 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ff [microtek] ========== Scanner Inquiry Report ========== [microtek] ===== Scanner ID... [microtek] Device Type Code: 0x06 [microtek] Model Code: 0x5d [microtek] Vendor Name: 'AGFA ' Model Name: 'DUOSCAN ' [microtek] Vendor Specific String: 'SCSI FW V3.6 CTL5380' [microtek] Firmware Rev: '2.30' [microtek] SCSI F/W version: 0.0 Scanner F/W version: 0.1 [microtek] Response data format: 0x01 [microtek] ===== Imaging Capabilities... [microtek] Modes: Lineart Halftone Gray Color (OnePass) [microtek] Resolution Step Sizes: 1% 5% Expanded Resolution Support? yes [microtek] Supported Bits Per Sample: 4 8 10 12 [microtek] Max. document size code: 0x06 [microtek] Max. document size: 8299 x 13499 pixels [microtek] Frame units: pixels 1/8"'s [microtek] # of built-in halftones: 12 Downloadable patterns? Yes [microtek] Data Compression: [microtek] Contrast Settings: 14 Exposure Settings: 74 [microtek] Adjustable Shadow/Highlight? yes Adjustable Midtone? yes [microtek] Digital brightness/offset? yes [microtek] Gamma Table Size: 4096 entries of 2 bytes (max. depth: 12) [microtek] ===== Source Options... [microtek] Feed type: flatbed ADF support? yes [microtek] Document Feeder Support? yes Feeder Backtracking? yes [microtek] Feeder Installed? no Feeder Ready? no [microtek] Transparency Adapter Installed? yes [microtek] Fast Color Prescan? no [microtek] Selectable Transfer Format? no [microtek] Color Transfer Sequence: line-by-line, non-sequential with headers [microtek] Three pass scan support? no [microtek] ModeSelect-1 and ModeSense-1 Support? yes [microtek] Can Disable Linearization Table? no [microtek] Can Disable Start-of-Scan Recalibration? no [microtek] Internal expanded expansion? no [microtek] ====== End of Scanner Inquiry Report ======= [sanei_debug] Setting debug level of sanei_scsi to 255. [sanei_scsi] sanei_scsi_open: device name /dev/scanner is not valid [sanei_debug] Setting debug level of sanei_scsi to 255. [sanei_scsi] cmd2: cmd_size:6 src_size:0 dst_size:0 isWrite:1 [sanei_scsi] isWrite src_size:0 [sanei_scsi] Executing command [sanei_scsi] ExecuteTaskSync OK Transferred 0 bytes [sanei_scsi] cmd2: cmd_size:6 src_size:9 dst_size:0 isWrite:1 [sanei_scsi] isWrite src_size:9 [sanei_scsi] Executing command [sanei_scsi] ExecuteTaskSync OK Transferred 9 bytes [sanei_scsi] cmd2: cmd_size:6 src_size:0 dst_size:0 isWrite:1 [sanei_scsi] isWrite src_size:0 [sanei_scsi] Executing command [sanei_scsi] ExecuteTaskSync OK Transferred 0 bytes [sanei_scsi] cmd2: cmd_size:10 src_size:8192 dst_size:0 isWrite:1 [sanei_scsi] isWrite src_size:8192 [sanei_scsi] Executing command [sanei_scsi] ExecuteTaskSync OK Transferred 8192 bytes [sanei_scsi] cmd2: cmd_size:6 src_size:11 dst_size:0 isWrite:1 [sanei_scsi] isWrite src_size:11 [sanei_scsi] Executing command [sanei_scsi] ExecuteTaskSync OK Transferred 11 bytes [sanei_scsi] cmd2: cmd_size:6 src_size:10 dst_size:0 isWrite:1 [sanei_scsi] isWrite src_size:10 [sanei_scsi] Executing command [sanei_scsi] ExecuteTaskSync OK Transferred 10 bytes [sanei_scsi] cmd2: cmd_size:6 src_size:0 dst_size:0 isWrite:1 [sanei_scsi] isWrite src_size:0 [sanei_scsi] Executing command [sanei_scsi] ExecuteTaskSync OK Transferred 0 bytes [sanei_scsi] cmd2: cmd_size:6 src_size:0 dst_size:0 isWrite:1 [sanei_scsi] isWrite src_size:0 [sanei_scsi] Executing command [sanei_scsi] ExecuteTaskSync OK Transferred 0 bytes [sanei_scsi] cmd2: cmd_size:6 src_size:0 dst_size:6 isWrite:0 [sanei_scsi] isRead dst_size:6 [sanei_scsi] Executing command [sanei_scsi] ExecuteTaskSync OK Transferred 6 bytes [sanei_scsi] taskStatus = 0x00000002 [sanei_scsi] cmd2: cmd_size:6 src_size:0 dst_size:0 isWrite:1 [sanei_scsi] isWrite src_size:0 [sanei_scsi] Executing command [sanei_scsi] ExecuteTaskSync OK Transferred 0 bytes scanimage: sane_start: Error during device I/O