Thanks for the information.  I was under the impression that the T=CL spec 
(ISO/IEC 14443-4 -- http://www.sc17.com/documents/17n1689.ZIP) allowed for 
a mapping of APDUs similar to T=1, but I could see why this might be too 
new for common usage.

Both Gemplus and Philips sell PC-based ISO 14443 readers, so it should be 
possible in theory.

Thanks again


On Wed, 10 Jul 2002, Matthias Bruestle wrote:

> On Tue, Jul 09, 2002 at 10:27:20AM -0400, dave engberg wrote:
> > Has anyone developed MUSCLE drivers for contactless readers/antennas such 
> > as Gemplus's GCA680?
> 
> MUSCLE implements PC/SC, which is targeted for contact based smart cards.
> So the GCA680, which is btw. a MIFARE reader, has two properties which
> makes is a bit difficult to use PC/SC with it:
> 
> 1) The cards are not smart cards but prorietary memory cards with some
>    security logic. So there are no APDUs which could be sent to the card.
>    It would be possible to define APDUs which are interpreded by the
>    reader(driver) like in the CT-BCS specs, but there is no standard.
> 
> 2) The cards are not contact based but contactless. There is e.g. no
>    slot. One way to specify a card could be to give the driver a
>    card ID prefix and ask for a proper card for it. Another way could
>    be to interate through them until a card with the correct content
>    is found. Both is AFAIK not supported by the current PC/SC.
> 
> 
> Mahlzeit
> endergone Zwiebeltuete



***************************************************************
Unix Smart Card Developers - M.U.S.C.L.E.
(Movement for the Use of Smart Cards in a Linux Environment)
http://www.linuxnet.com/
To unsubscribe send an email to [EMAIL PROTECTED] with
unsubscribe sclinux
***************************************************************

Reply via email to