Le jeudi 08 ao�t 2002 � 17:27:49, Victor Tarasov a �crit:
> Hi,

Hello,

> I am using GemPC410  with  Oberthur AuthentIC smart card.
> 
> Option  IFD_CMD_ICC_POWER_UP_OPT_AUTO_PPS_MNGT
> in the POWER_UP command is not working.
> 
> Smart card returns ATR without error after power up with this option.
> But then it do not works properly.
> Its ICC_STATUS is:  06 02 18 00 0A 00.
> 
> Smart card works correctly with IFD_CMD_ICC_POWER_UP_OPT_NO_PPS_MNGT
> option of the POWER_UP command.
> Its ICC status is 06 02 11 00 0A 00.

I am not sure to understand correctly your problem.

Your card answers correctly to the ATR with
IFD_CMD_ICC_POWER_UP_OPT_AUTO_PPS_MNGT but stop working after some time.
Can you describe what happens then? What's wrong?

Can you give us the ATR of your Oberthur AuthentIC smart card?

> Where can I find description of the values, returned by IFD commands,
> please?

Which values returned by which IFD commands? More info please.
You can find the GemCore doc here [1].

Bye,

[1] http://www.linuxnet.com/documentation/files/e5221031.pdf

-- 
 Dr. Ludovic Rousseau                        [EMAIL PROTECTED]
 -- Normaliser Unix c'est comme pasteuriser le Camembert, L.R. --
***************************************************************
Unix Smart Card Developers - M.U.S.C.L.E.
(Movement for the Use of Smart Cards in a Linux Environment)
http://www.linuxnet.com/
To unsubscribe send an email to [EMAIL PROTECTED] with
unsubscribe sclinux
***************************************************************