Le jeudi 08 ao�t 2002 � 17:27:49, Victor Tarasov a �crit: > Hi, Hello,
> I am using GemPC410 with Oberthur AuthentIC smart card. > > Option IFD_CMD_ICC_POWER_UP_OPT_AUTO_PPS_MNGT > in the POWER_UP command is not working. > > Smart card returns ATR without error after power up with this option. > But then it do not works properly. > Its ICC_STATUS is: 06 02 18 00 0A 00. > > Smart card works correctly with IFD_CMD_ICC_POWER_UP_OPT_NO_PPS_MNGT > option of the POWER_UP command. > Its ICC status is 06 02 11 00 0A 00. I am not sure to understand correctly your problem. Your card answers correctly to the ATR with IFD_CMD_ICC_POWER_UP_OPT_AUTO_PPS_MNGT but stop working after some time. Can you describe what happens then? What's wrong? Can you give us the ATR of your Oberthur AuthentIC smart card? > Where can I find description of the values, returned by IFD commands, > please? Which values returned by which IFD commands? More info please. You can find the GemCore doc here [1]. Bye, [1] http://www.linuxnet.com/documentation/files/e5221031.pdf -- Dr. Ludovic Rousseau [EMAIL PROTECTED] -- Normaliser Unix c'est comme pasteuriser le Camembert, L.R. -- *************************************************************** Unix Smart Card Developers - M.U.S.C.L.E. (Movement for the Use of Smart Cards in a Linux Environment) http://www.linuxnet.com/ To unsubscribe send an email to [EMAIL PROTECTED] with unsubscribe sclinux ***************************************************************