Thank you Mark for your response,

In carrying out the test you recommended I realised that I had set the 
integrator to sd, in such a case the tcoupl parameter is ignored. This explains 
my well behave temperature in the absence of setting a tcoupl option. When I 
wrote the input file originally (months ago) I must have known what I was doing 
but then we live, we learn, we forget.

Regards

Charlie
  -- 
gmx-users mailing listgmx-users@gromacs.org
http://lists.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
Please don't post (un)subscribe requests to the list. Use the 
www interface or send it to gmx-users-requ...@gromacs.org.
Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

[gmx-users] Tcoupl default setting

2011-04-21 Thread Charlie Forde

Dear All,

I had intended to perform an NPT simulation, however although I selected a 
barostat I omitted to select a thermostat, nevertheless I did set tc_grps= 
system, tau_t = 0.1 and ref_t= 300. My temperature appears to fluctuate around 
the desired 300 K. My question is, by setting tau_t and  ref_t has a default 
thermostat also been turned on by default and if so which one, or have I not 
performed an NPT but rather an NPE simulation with my apparent well behaved 
temperature just being coincidental. Needless to say there is no mention of 
tcoupl in the output file.

Regards

Charlie.
  -- 
gmx-users mailing listgmx-users@gromacs.org
http://lists.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
Please don't post (un)subscribe requests to the list. Use the 
www interface or send it to gmx-users-requ...@gromacs.org.
Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

[gmx-users] Tcoupl default setting‏

2011-04-21 Thread Charlie Forde







Dear All,

I had intended to perform an NPT simulation, however
although I selected a barostat I omitted to select a thermostat,
nevertheless I did set tc_grps= system, tau_t = 0.1 and ref_t= 300. My
temperature appears to fluctuate around the desired 300 K. My question
is, by setting tau_t and  ref_t has a default thermostat also been
turned on by default and if so which one, or have I not performed an
NPT but rather an NPE simulation with my apparent well behaved
temperature just being coincidental. Needless to say there is no
mention of tcoupl in the output file.

Regards

Charlie.


Apologies for possible double posting
  -- 
gmx-users mailing listgmx-users@gromacs.org
http://lists.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
Please don't post (un)subscribe requests to the list. Use the 
www interface or send it to gmx-users-requ...@gromacs.org.
Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

[gmx-users] Amb2gmx

2010-09-14 Thread Charlie Forde
Dear all,

Lennard Jones radius parameters are converted between gromacs and amber with 
the conversion factor (2**(5/6))/10 in the amb2gmx script. While I understand 
that the 10 takes care of the Angstrom to nanometers conversion I do not 
understand the origin of the 2 to the power of 5/6. I would like to know how it 
arises?

Thanks

Charile
  -- 
gmx-users mailing listgmx-users@gromacs.org
http://lists.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
Please don't post (un)subscribe requests to the list. Use the 
www interface or send it to gmx-users-requ...@gromacs.org.
Can't post? Read http://www.gromacs.org/Support/Mailing_Lists