Control: usertag -1 bsp-2019-04-se-gothenburg
Hi there,
strace(1) shows a select(2) syscall indicating that the socket is ready for
both read and write, but is later blocking on a read(2) without any
write(2) taking place.
select(8, [3], [3], NULL, {tv_sec=180, tv_usec=0}) = 2 (in [3], out [
On Wed, 12 Dec 2018 16:34:34 +0100, cyri...@bollu.be wrote:
> I've investigated a little bit this problem,
Great, thank you!
> and I wonder if this could be
> caused by a bug in Net::SSLeay 1.85 which seems to be resolved in version
> 1.86_06 (not yet released on CPAN) via
> https://github.com
Hello,
I've investigated a little bit this problem, and I wonder if this could
be caused by a bug in Net::SSLeay 1.85 which seems to be resolved in
version 1.86_06 (not yet released on CPAN) via
https://github.com/radiator-software/p5-net-ssleay/pull/56/commits/f67e75f2b50fa72da9a5111abc13b2bd