Hey Heiko,
I have tested your series and it successfully fixes the problem with the
2nd camera when HDMI is connected at boot. Besides that the patch looks
good and my tests have confirmed that both cameras have the same output
quality when I exchange the connected ISP instances.
Tested-by: Seba
Am Mittwoch, 10. Februar 2021, 12:10:14 CET schrieb Heiko Stuebner:
> The rk3399 has two ISPs and right now only the first one is usable.
> The second ISP is connected to the TXRX dphy on the soc.
>
> The phy of ISP1 is only accessible through the DSI controller's
> io-memory, so this series adds
The rk3399 has two ISPs and right now only the first one is usable.
The second ISP is connected to the TXRX dphy on the soc.
The phy of ISP1 is only accessible through the DSI controller's
io-memory, so this series adds support for simply using the dsi
controller is a phy if needed.
That solution
3 matches