thank u
On Tue, Apr 12, 2016 at 2:45 PM, Deep Kiran wrote:
> Dear Mounika,
>
> for example of case5.m
>
> Write the code as:
>
> mpc = loadcase(case5);
> mpc.branch('branch number',6) = 'specify your line limit for the branch of
> your choice';
>
> I hope this helps!
>
>
Wow, its been 2 years of using Matpower and I was unaware of this setting.
Thank you Sir.
Best regards,
Deep Kiran
On 8 April 2016 at 19:37, Ray Zimmerman wrote:
> Your understanding is correct. However, with numerical algorithms such as
> the primal-dual interior point
Dear Mounika,
for example of case5.m
Write the code as:
mpc = loadcase(case5);
mpc.branch('branch number',6) = 'specify your line limit for the branch of
your choice';
I hope this helps!
Regards,
Deep Kiran
On 12 April 2016 at 14:15, Mounika Vanjarapu
wrote:
>
can anyone say how to change the power flow limits by writing the code but
not by editing the limits.like setting the limits to my wish for some
branches
Hello Jaroslaw,
I may be completely off, as I do not know the RTDS system you're using, but
I couldn't help noticing this sounds as if RTDS is using the "ZIP" (in your
case just Z,P) load model components *only for transients*, not for static
powerflow. But this is to be expected, because using