Some modems report Unknown as the operator name when failed to obtain
the actual value:
-- 'AT+COPS=3,0;+COPS?CR'
-- 'CRLF+COPS: 0,0,Unknown,0CRLFCRLFOKCRLF'
This patch prevents Unknown from being treated as a valid operator name.
---
src/mm-modem-helpers.c | 10 +-
1 files
On Thu, 2012-09-20 at 08:41 -0700, Ben Chan wrote:
Some modems report Unknown as the operator name when failed to obtain
the actual value:
-- 'AT+COPS=3,0;+COPS?CR'
-- 'CRLF+COPS: 0,0,Unknown,0CRLFCRLFOKCRLF'
This patch prevents Unknown from being treated as a valid operator name.