https://bugs.kde.org/show_bug.cgi?id=347470
--- Comment #6 from Philipp Rehs ---
I just compiled powerdevil-git with this patch and it seems to fix the problem
in a short test.
I will run it the next days and give you some feedback
--
You are receiving this mail because:
You are the assignee
https://bugs.kde.org/show_bug.cgi?id=347470
--- Comment #4 from Philipp Rehs ---
Your idea could be right. This time it happened when the second battery was
empty.
off-topic:
is there any way to give a priority to batteries? or give them differend names?
--
You are receiving this mail because
https://bugs.kde.org/show_bug.cgi?id=347470
--- Comment #3 from Philipp Rehs ---
philipp@philipp-t440s ~ $ upower -d
Device: /org/freedesktop/UPower/devices/line_power_AC
native-path: AC
power supply: yes
updated: Sa 09 Mai 2015 16:46:53 CEST (3 seconds ago
https://bugs.kde.org/show_bug.cgi?id=347470
Bug ID: 347470
Summary: Shutdown when one of two batteries is empty
Product: Powerdevil
Version: 5.3.0
Platform: Other
OS: other
Status: UNCONFIRMED
Severity: no
https://bugs.kde.org/show_bug.cgi?id=347470
Philipp Rehs changed:
What|Removed |Added
Platform|Other |Archlinux Packages
OS|other