RE: [Veritas-bu] Media Experation

2005-12-23 Thread Mark . Donaldson
One caveat to this all, don't confuse the volume expiration date, part of the VolDB & visible with the vmquery command, with the media expiration date. The the VolDB setting is the date that the tape is too old to continue to be used (not set by default). The latter is the date that the last image

Re: [Veritas-bu] Media Experation

2005-12-22 Thread David Rock
* Jim Peppas <[EMAIL PROTECTED]> [2005-12-23 00:52]: > Hi. > > Don't use the vmquery -deassignbyid command. It will only cause you > headaches. When using this command, the tapes are not cleaned up correctly > (see http://seer.support.veritas.com/docs/241574.htm). > When you want ot expire tape

RE: [Veritas-bu] Media Experation

2005-12-22 Thread Jim Peppas
Hi. Don't use the vmquery -deassignbyid command. It will only cause you headaches. When using this command, the tapes are not cleaned up correctly (see http://seer.support.veritas.com/docs/241574.htm). When you want ot expire tape always use the bpexpdate command. Only if this fails should you u

RE: [Veritas-bu] Media Experation

2005-12-19 Thread Williams, Kristopher L
e you don't see them going back to scratch. Thanks, Kris -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Martin, Jonathan (Contractor) Sent: Monday, December 19, 2005 10:10 AM To: WEAVER, Simon; veritas-bu@mailman.eng.auburn.edu Subject: RE: [Veritas-

RE: [Veritas-bu] Media Experation

2005-12-19 Thread WEAVER, Simon
- From: WEAVER, Simon [mailto:[EMAIL PROTECTED] Sent: Monday, December 19, 2005 10:05 AM To: Martin, Jonathan (Contractor); veritas-bu@mailman.eng.auburn.edu Subject: RE: [Veritas-bu] Media Experation By the way, you could use bpexpdate -m -d 0 if you want to force netbackup to move the tap

RE: [Veritas-bu] Media Experation

2005-12-19 Thread Martin, Jonathan \(Contractor\)
[mailto:[EMAIL PROTECTED] Sent: Monday, December 19, 2005 10:05 AM To: Martin, Jonathan (Contractor); veritas-bu@mailman.eng.auburn.edu Subject: RE: [Veritas-bu] Media Experation By the way, you could use bpexpdate -m -d 0 if you want to force netbackup to move the tapes into SCRATCH, assumin

RE: [Veritas-bu] Media Experation

2005-12-19 Thread WEAVER, Simon
Hello Martin Something to check. In 5.1, goto the Policies and expand this. Choose a policy , double click (if your windows) and goto the Schedules Tab). Double click on the schedule and there will be a section called "RETENTION" - this should show what the retention is set for within this

RE: [Veritas-bu] Media Experation

2005-12-19 Thread WEAVER, Simon
By the way, you could use bpexpdate -m -d 0 if you want to force netbackup to move the tapes into SCRATCH, assuming that has been configured and the tapes have no images on there that are needed! HTH Simon Weaver Technical Support Windows Domain Administrator EADS Astrium Tel: 02392-708598