No prob Rick -- yeah it could be that, it's Mohawk outdoor ethernet
(don't know the specific model # off hand). Could also be since they
only had two left in stock when I ordered that by the time my order was
processed they slipped me another, smaller sized model :-)
Thanks.
RickG wrote:
>
Sorry to hear that. My cable is 24 gauge, cat5e outdoor grade and the
beads do fit. Maybe your cable has a thicker jacket?
On Sun, May 2, 2010 at 11:02 PM, Steven G McGehee wrote:
> Hi Rick,
>
> I bought a couple of those beads that you linked to a few weeks ago when
> this was a hot topic -- but
Right - the ferrite material needs to be continuous.
The plastic bit is irrelevant.
Josh Luthman
Office: 937-552-2340
Direct: 937-552-2343
1100 Wayne St
Suite 1337
Troy, OH 45373
“Success is not final, failure is not fatal: it is the courage to continue
that counts.”
--- Winston Churchill
On M
Make sure it pulls the core together (no spaces between halves) or it will lose
it's effectiveness.
Greg
On May 2, 2010, at 10:57 PM, Josh Luthman wrote:
> Wrap it around and zip tie it together. I've not had them in my hand
> but the plastic tabs are unlikely to hold over time.
>
> On 5/2/10
Wrap it around and zip tie it together. I've not had them in my hand
but the plastic tabs are unlikely to hold over time.
On 5/2/10, Steven G McGehee wrote:
> Hi Rick,
>
> I bought a couple of those beads that you linked to a few weeks ago when
> this was a hot topic -- but my outdoor (24 gauge)
Hi Rick,
I bought a couple of those beads that you linked to a few weeks ago when
this was a hot topic -- but my outdoor (24 gauge) cable is too large to
fit in them (i.e., the enclosure doesn't snap closed). Do you use an
outdoor cable of smaller diameter than 24 gauge, or do you tape the
fer
Yes, I put them on the power side of the Ethernet cable running up to
the radios.
On Sun, May 2, 2010 at 8:29 PM, Josh Luthman
wrote:
> I was thinking 1 would be needed per line, but only based on where I've seen
> ferrite in the past.
>
> You are saying you do it on the power side of the poe, ri
If you did two I'd put them together or if you space them make sure you don't
space them a half wavelength apart so as to avoid have a section between the
beads that would be resonant. The reason for spacing them might be to keep the
RF away from the other equipment so you don't have the shielde
What about the front to back ratio with the yagis? That's really gotta suck
unless you're going with 5mhz channels.
- Original Message -
From: "Josh Luthman"
To: "WISPA General List"
Sent: Sunday, May 02, 2010 8:33 PM
Subject: Re: [WISPA] Looking for iput on 900MHz
H-PolSectorChoice
I know for a fact at least one person on the other list you and I share is
doing it. It was suggested to me a few months ago.
Josh Luthman
Office: 937-552-2340
Direct: 937-552-2343
1100 Wayne St
Suite 1337
Troy, OH 45373
“Success is not final, failure is not fatal: it is the courage to continue
I was thinking 1 would be needed per line, but only based on where I've seen
ferrite in the past.
You are saying you do it on the power side of the poe, right?
Josh Luthman
Office: 937-552-2340
Direct: 937-552-2343
1100 Wayne St
Suite 1337
Troy, OH 45373
“Success is not final, failure is not fat
I put them on the end at the ground before the POE. Not sure if two
would make any difference.
On Sun, May 2, 2010 at 2:42 PM, Josh Luthman
wrote:
> For these ferrite chokes do you put one on the cable anywhere? At one end?
> Two (one at each end)?
>
> Josh Luthman
> Office: 937-552-2340
> Direc
Is anyone here currently using 3 YAGI's to achieve 360 degree coverage with
3 Canopy 900 radio's? How is this working for you?
Reason I am asking is because the 3 sectors are so huge that the windload on
the tower is too much and looking for alternatives.
Kurt Fankhauser
WAVELINC
P.O. Box 126
Buc
Did you guys change your redirect page very much? I changed it in two
ways. I made the reasons and fixes line up and make sense (because removing
a virus would never update their account) and added the IP address at the
bottom so I can simply add their new computer/router/etc to their account
wit
For these ferrite chokes do you put one on the cable anywhere? At one end?
Two (one at each end)?
Josh Luthman
Office: 937-552-2340
Direct: 937-552-2343
1100 Wayne St
Suite 1337
Troy, OH 45373
“Success is not final, failure is not fatal: it is the courage to continue
that counts.”
--- Winston Ch
15 matches