Q223757….
We were apparently using a value (ReplicationSourceDC
in this case) that does not get read during a demotion, only during promotions.
Larry A. Duncan, MCSA/MCSE
Directory Services Engineer/
Systems Management Consultant
[EMAIL PROTECTED]
ph. 615.598.0241
-Original Message-
From:
[EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]] On Behalf Of Larry A. Duncan
Sent: Friday,
November 08, 2002 10:31 AM
To: [EMAIL PROTECTED]
Subject: [ActiveDir] DCPromo w/
Answer File
We are processing some 230 DCs for
demotion over the weekend. To facilitate this, we’ve created an answer
file that specifies that the ReplicationSourceDC is to use during the demotion.
But, during the demotion, we’re seeing it not use the named source. Any
suggestions?
Larry A. Duncan, MCSA/MCSE
Directory Services Engineer/
Systems Management Consultant
[EMAIL PROTECTED]
ph. 615.598.0241