Re: Checkin multiple tapes to 3494 library

2003-02-27 Thread Allen Barth
Agreed!   I have gotten numerous boxes of 'prelabeled' tapes only to find
that the vendor had only applied the barcodes.

Al




Richard Sims [EMAIL PROTECTED]
Sent by: ADSM: Dist Stor Manager [EMAIL PROTECTED]
02/26/03 12:55 PM
Please respond to ADSM: Dist Stor Manager


To: [EMAIL PROTECTED]
cc:
Subject:Re: Checkin multiple tapes to 3494 library


The tapes are pre-labeled and initialized.

I would advised *always* doing your own media labeling of incoming
volumes, and to not assume that the media vendor has done it right.
This also provides an initial test of tape writeability.

  Richard Sims, BU


Re: Checkin multiple tapes to 3494 library

2003-02-26 Thread Tommy Templeton
The tapes are pre-labeled and initialized.
This is my response when I do a q libr.  According to the output below, I
don't think the library is shared. We do share a robotics unit with another
agency but they have their own library.

   Library Name: 3494VTS
  Library Type: 349X
Device: /dev/lmcp0
  Private Category: 300
  Scratch Category: 301
  External Manager:
Shared: No
   LanFree:
ObeyMountRetention:

- Original Message -
From: Allen Barth [EMAIL PROTECTED]
To: [EMAIL PROTECTED]
Sent: Tuesday, February 25, 2003 4:19 PM
Subject: Re: Checkin multiple tapes to 3494 library


 You got  several answers, but I got questions for you.

 1. Is the 3494 shared?
 2. Do you know if the tapes are initialized?

 If the 3494 is shared, you can't just do a search=yes because you may very
 well get tapes that *shouldn't* belong to ITSM
 If the tapes aren't initialized then you can't just do a checkin.  You'll
 need to do a DSMLABEL or LABEL LIBV





 Tommy Templeton [EMAIL PROTECTED]
 Sent by: ADSM: Dist Stor Manager [EMAIL PROTECTED]
 02/25/03 01:30 PM
 Please respond to ADSM: Dist Stor Manager


 To: [EMAIL PROTECTED]
 cc:
 Subject:Checkin multiple tapes to 3494 library


 Hi *SM'ers

 Is there a way to check in multiple new volumes (with barcodes) to a 3494
 library as scratch?

 Tommy Templeton
 Senior System Administrator
 DFA-MMRS
 601-359-3106
 e-mail - [EMAIL PROTECTED]


Re: Checkin multiple tapes to 3494 library

2003-02-26 Thread Richard Sims
The tapes are pre-labeled and initialized.

I would advised *always* doing your own media labeling of incoming
volumes, and to not assume that the media vendor has done it right.
This also provides an initial test of tape writeability.

  Richard Sims, BU


Checkin multiple tapes to 3494 library

2003-02-25 Thread Tommy Templeton
Hi *SM'ers

Is there a way to check in multiple new volumes (with barcodes) to a 3494 library as 
scratch? 

Tommy Templeton
Senior System Administrator
DFA-MMRS
601-359-3106
e-mail - [EMAIL PROTECTED]


Re: Checkin multiple tapes to 3494 library

2003-02-25 Thread Bob Booth - UIUC
checkin libv libname search=yes checkl=yes/no status=scratch

bob

On Tue, Feb 25, 2003 at 01:30:52PM -0600, Tommy Templeton wrote:
 Hi *SM'ers

 Is there a way to check in multiple new volumes (with barcodes) to a 3494 library as 
 scratch?

 Tommy Templeton
 Senior System Administrator
 DFA-MMRS
 601-359-3106
 e-mail - [EMAIL PROTECTED]


Re: Checkin multiple tapes to 3494 library

2003-02-25 Thread Fred Johanson
checki libv libname sea=y devt=whatever stat=scr volr=1stbarcode,lastbarcode

At 01:30 PM 2/25/2003 -0600, you wrote:
Hi *SM'ers

Is there a way to check in multiple new volumes (with barcodes) to a 3494
library as scratch?
Tommy Templeton
Senior System Administrator
DFA-MMRS
601-359-3106
e-mail - [EMAIL PROTECTED]


Re: Checkin multiple tapes to 3494 library

2003-02-25 Thread Lawrence Clark
load them in the hopper and get them in the library 1st, before entering
the checkin command.

 [EMAIL PROTECTED] 02/25/03 02:30PM 
Hi *SM'ers

Is there a way to check in multiple new volumes (with barcodes) to a
3494 library as scratch?

Tommy Templeton
Senior System Administrator
DFA-MMRS
601-359-3106
e-mail - [EMAIL PROTECTED]


Re: Checkin multiple tapes to 3494 library

2003-02-25 Thread Trinh, Tony
Tommy,

Yup, the easiest way that I found to check in multiple new volumes to a 3494
library is creating a text file like below. Then log in to TSM and run a
macro against that file...show below too... Hopefully these tapes have
already been formatted.



$ more checkin
checkin libv ids01atl1 1a1321 devt=3590 status=scratch
checkin libv ids01atl1 1a1323 devt=3590 status=scratch
checkin libv ids01atl1 1a1330 devt=3590 status=scratch
checkin libv ids01atl1 1a1331 devt=3590 status=scratch
checkin libv ids01atl1 1a1334 devt=3590 status=scratch


Session established with server I01SV600: Solaris 7/8
  Server Version 4, Release 2, Level 1.9
  Server date/time: 02/25/03   20:37:55  Last access: 02/25/03   20:22:15


tsm: I01SV600macro /tmp/checkin




-Original Message-
From: Tommy Templeton [mailto:[EMAIL PROTECTED]
Sent: Tuesday, February 25, 2003 11:31 AM
To: [EMAIL PROTECTED]
Subject: Checkin multiple tapes to 3494 library

Hi *SM'ers

Is there a way to check in multiple new volumes (with barcodes) to a 3494
library as scratch?

Tommy Templeton
Senior System Administrator
DFA-MMRS
601-359-3106
e-mail - [EMAIL PROTECTED]


Re: Checkin multiple tapes to 3494 library

2003-02-25 Thread Allen Barth
You got  several answers, but I got questions for you.

1. Is the 3494 shared?
2. Do you know if the tapes are initialized?

If the 3494 is shared, you can't just do a search=yes because you may very
well get tapes that *shouldn't* belong to ITSM
If the tapes aren't initialized then you can't just do a checkin.  You'll
need to do a DSMLABEL or LABEL LIBV





Tommy Templeton [EMAIL PROTECTED]
Sent by: ADSM: Dist Stor Manager [EMAIL PROTECTED]
02/25/03 01:30 PM
Please respond to ADSM: Dist Stor Manager


To: [EMAIL PROTECTED]
cc:
Subject:Checkin multiple tapes to 3494 library


Hi *SM'ers

Is there a way to check in multiple new volumes (with barcodes) to a 3494
library as scratch?

Tommy Templeton
Senior System Administrator
DFA-MMRS
601-359-3106
e-mail - [EMAIL PROTECTED]


Re: Checkin multiple tapes to 3494 library

2003-02-25 Thread Lawrence Clark
lookat the checkin libvolume command

checkin libv libname volr=lownumber,highnumber stat=scr dev=3590

 [EMAIL PROTECTED] 02/25/03 02:30PM 
Hi *SM'ers

Is there a way to check in multiple new volumes (with barcodes) to a
3494 library as scratch?

Tommy Templeton
Senior System Administrator
DFA-MMRS
601-359-3106
e-mail - [EMAIL PROTECTED]