James,
I tried to use the LBTEST.EXE but this errors on every command which made
me very suspicious that I have not configured the drive/autochanger
correctly this is why I posed this message and wondered if any one else is
using one of these drives and what the setting are?
I will post tomorrow the "ADSMDLIST.EXE FILENAME ." as you suggested
perhaps there is some clue there
Regards,
Geoff Pusey
Tivoli Advisory Consultant
Tivoli Systems.
Office : +44 (0)1753 896896
Mobile : +44 (0) 780 8203704
Email: [EMAIL PROTECTED]
James Thompson [EMAIL PROTECTED]@VM.MARIST.EDU on 12/01/2000 04:31:34
PM
Please respond to "ADSM: Dist Stor Manager" [EMAIL PROTECTED]
Sent by: "ADSM: Dist Stor Manager" [EMAIL PROTECTED]
To: [EMAIL PROTECTED]
cc:
Subject: Re: Install problem with a 3502-108 DLT changer
First off you should upgrade from the 3.7.0.0 GA code.
Secondly, to see if you have it set correctly, post the output
of ADSMDLIST.EXE FILENAME . This executable is located in the UTILS
directory where TSM is installed. You can also play around with LBTEST.EXE
in the same directory. LBTEST.EXE allows you to move tapes around in the
library.
James Thompson
From: Geoff Pusey [EMAIL PROTECTED]
Reply-To: "ADSM: Dist Stor Manager" [EMAIL PROTECTED]
To: [EMAIL PROTECTED]
Subject: Install problem with a 3502-108 DLT changer
Date: Fri, 1 Dec 2000 14:57:59 +
Hi,
I hope some one can verify if I have installed and configured this drive
correctly.
I have a NT 4 with sp6 in a NT cluster environment. with "Storage
Management Server for Windows NT - Version 3, Release 7, Level 0.0"
tsm: NMRIOESRV01q drive
Library Name Drive NameDevice Type DeviceON LINE
---
---
LB0.0.0.3 MT1.0.0.3 DLT MT1.0.0.3 Yes
**
*** --- Q VOLUME
**
Volume Name Storage
Device Estimated Pct Volume
Pool
Name Class Name Capacity Util Status
(MB)
--- -- -
-
D:\ADSMDATA\DISK1.DSMBACKUPPOOL DISK25.0
98.4 On-Line
IOE1 DLTPOOL1
DLTCLASS1 35,840.00.0 Filling
The Library was set up as element = 16
As all the 3502 drives linked me to this web site and as I only have one
drive I thought it must be element 16. Is this right?
IBM 3502-314
Device
SCSI ID
Device Name
Tape drive 1 (element 16)
__
__
Tape drive 2 (element 17)
__
__
Tape drive 3 (element 18)
__
__
Robot
__
__
Notes:
1.The following options should be
set during configuration:
Enable barcode
Autoload cartridge - NO
Auto Cleaning - NO (The
cleaning cartridge must be in the last slot)
Ramdom mode
My problem is that when I do a backup and it migrates to the library I get
the error no space left in volume? Is this a problem with the library or
my
config?
I can read in new tapes and label them, but I am unable to copy any data
to
them.
Any suggestions would be most appreciated
Regards,
Geoff Pusey
Tivoli Advisory Consultant
Tivoli Systems.
Office : +44 (0)1753 896896
Mobile : +44 (0) 780 8203704
Email: [EMAIL PROTECTED]
_
Get more from the Web. FREE MSN Explorer download :
http://explorer.msn.com