Re: FC-SCSI Bridge issues
Hi Eric We had some similar problems while integrating a SAN with StorageNet (Brocade) switches and the Stornet 3200. Problems disapeared after a firmware upgrade of the switch and the bridges. Thanks and have a good day Gaetano Bisaz
Re: FC/ SCSI
We have seen 60MB/sec into a 3590. It is not easy, because disk is SO SLOW (even stripe sets) when compared to tape with high compression ratios (4 to 1). Our test was DB2 in a Winterhawk II node in an SP using highly optimized Shark disk over fibre. The tape drive was on another Winterhawk II node connected via SP switch. All disk and tape was fibre. Orville L. Lantto Datatrend Technologies, Inc. 121 Cheshire Lane #700 Minnetonka, MN 55305 Email: [EMAIL PROTECTED] V: 952-931-1203 F: 952-931-1293 C: 612-770-9166 "Dearman, Richard" <[EMAIL PROTECTED]> Sent by: "ADSM: Dist Stor Manager" <[EMAIL PROTECTED]> 01/28/02 10:51 AM Please respond to "ADSM: Dist Stor Manager" To: [EMAIL PROTECTED] cc: Subject:Re: FC/ SCSI I have tested this scenario moving to scsi connected 3590e's and fc connected 3590e's. Using scsi to got about 20Mb/s and fc about 25Mb/s. I'm using hardware compressions. I haven't been able to get the high levels of throughput the IBM claims you can get from moving to fc. Although I haven't tried testing using the move data command yet. My test were coming from my disk pool to tape. -Original Message- From: Felix Muelbaier [mailto:[EMAIL PROTECTED]] Sent: Monday, January 28, 2002 8:24 AM To: [EMAIL PROTECTED] Subject: FC/ SCSI Hi everybody has anyone some experience with this environment. TSM Server Version 4.1.3 OS=AIX 4.3.3 ML8 3494 Library 4 Tapes 3590E 2 Tapes with SCSI 2 Tapes FC IBM says the 3590E a much more faster with the FC adapter. So we want to put one FC Card into our SP and test it. Then the TSM server should run with SCSI and FC tapes. Later will upgrade the next two drives and move the TSM SERVER to a new Hardware. Mit freundlichen Grüßen Felix Mülbaier bebit Informationstechnik GmbH Besselstraße 26 D-68219 Mannheim http://www.bebit.de mailto: [EMAIL PROTECTED]
Re: FC/ SCSI
Even though you're using a bigger pipe to get to the drives, you're still limited to the speed the drive can read/write data to the heads. Bill Boyer -Original Message- From: ADSM: Dist Stor Manager [mailto:[EMAIL PROTECTED]]On Behalf Of Jeff Bach Sent: Monday, January 28, 2002 11:19 AM To: [EMAIL PROTECTED] Subject: Re: FC/ SCSI They are the same speed. I use client compression (and hardware). 13-15 Megs per second going from SCSI to SCSI, fiber to fiber, SCSI to fiber. Testes using move data commands. LTO tape drives are about the same. Jeff Bach > -Original Message- > From: Felix Muelbaier [SMTP:[EMAIL PROTECTED]] > Sent: Monday, January 28, 2002 8:24 AM > To: [EMAIL PROTECTED] > Subject: FC/ SCSI > > Hi everybody > > has anyone some experience with this environment. > TSM Server Version 4.1.3 OS=AIX 4.3.3 ML8 > 3494 Library 4 Tapes 3590E > 2 Tapes with SCSI 2 Tapes FC > > IBM says the 3590E a much more faster with the FC adapter. So we want to > put one FC Card into our SP and test it. > Then the TSM server should run with SCSI and FC tapes. Later will > upgrade > the next two drives and move the TSM SERVER to a new Hardware. > > > > > > Mit freundlichen Grüßen > Felix Mülbaier > > > > bebit Informationstechnik GmbH > Besselstraße 26 > D-68219 Mannheim > http://www.bebit.de > > mailto: [EMAIL PROTECTED] ** This email and any files transmitted with it are confidential and intended solely for the individual or entity to whom they are addressed. If you have received this email in error destroy it immediately. **
Re: FC/ SCSI
They are the same speed. I use client compression (and hardware). 13-15 Megs per second going from SCSI to SCSI, fiber to fiber, SCSI to fiber. Testes using move data commands. LTO tape drives are about the same. Jeff Bach > -Original Message- > From: Felix Muelbaier [SMTP:[EMAIL PROTECTED]] > Sent: Monday, January 28, 2002 8:24 AM > To: [EMAIL PROTECTED] > Subject: FC/ SCSI > > Hi everybody > > has anyone some experience with this environment. > TSM Server Version 4.1.3 OS=AIX 4.3.3 ML8 > 3494 Library 4 Tapes 3590E > 2 Tapes with SCSI 2 Tapes FC > > IBM says the 3590E a much more faster with the FC adapter. So we want to > put one FC Card into our SP and test it. > Then the TSM server should run with SCSI and FC tapes. Later will > upgrade > the next two drives and move the TSM SERVER to a new Hardware. > > > > > > Mit freundlichen Grüßen > Felix Mülbaier > > > > bebit Informationstechnik GmbH > Besselstraße 26 > D-68219 Mannheim > http://www.bebit.de > > mailto: [EMAIL PROTECTED] ** This email and any files transmitted with it are confidential and intended solely for the individual or entity to whom they are addressed. If you have received this email in error destroy it immediately. **
Re: FC/ SCSI
I have tested this scenario moving to scsi connected 3590e's and fc connected 3590e's. Using scsi to got about 20Mb/s and fc about 25Mb/s. I'm using hardware compressions. I haven't been able to get the high levels of throughput the IBM claims you can get from moving to fc. Although I haven't tried testing using the move data command yet. My test were coming from my disk pool to tape. -Original Message- From: Felix Muelbaier [mailto:[EMAIL PROTECTED]] Sent: Monday, January 28, 2002 8:24 AM To: [EMAIL PROTECTED] Subject: FC/ SCSI Hi everybody has anyone some experience with this environment. TSM Server Version 4.1.3 OS=AIX 4.3.3 ML8 3494 Library 4 Tapes 3590E 2 Tapes with SCSI 2 Tapes FC IBM says the 3590E a much more faster with the FC adapter. So we want to put one FC Card into our SP and test it. Then the TSM server should run with SCSI and FC tapes. Later will upgrade the next two drives and move the TSM SERVER to a new Hardware. Mit freundlichen Grüßen Felix Mülbaier bebit Informationstechnik GmbH Besselstraße 26 D-68219 Mannheim http://www.bebit.de mailto: [EMAIL PROTECTED]