cleaning cartridge for 3494 tape library

2000-08-28 Thread Phillip Guan

Hi all,

We would like to checkin some cleaning cartridge to 3494 tape library. We
put in four cleaning cartridges already through I/O station, do we need to
run 'checkin' from TSM to check in them or check in from 3494 workstation?
Or do nothing?

'mtlib -l /dev/lmcp0 -qI -v' shows no cleaning cartridge but 'mtlib -l
/dev/lmcp0 -qL' shows 'avail 3590 cleaner cycles..398'. What does it mean?

Thanks.

Best regards,
Phillip Guan
Sansia System Solutions
 Bowers Avenue, Suite 239
Santa Clara, CA 95054
Voice: 408.844.8808
Fax: 408.844.9801



Re: cleaning cartridge for 3494 tape library

2000-08-28 Thread Richard Sims

We would like to checkin some cleaning cartridge to 3494 tape library. We
put in four cleaning cartridges already through I/O station, do we need to
run 'checkin' from TSM to check in them or check in from 3494 workstation?
Or do nothing?

TSM is not involved with cleaner cartridges in libraries and drives which
initiate their own cleaning, like the 3494.  You need to apply barcode labels
which conform to the definition you made for the Cleaner Volume Mask in the
Library Manager, and also there define the cleaning interval.
Refer to your 3494 Operator Guide and the redbook
IBM Magstar Tape Products Family: A Practical Guide (SG24-4632).

  Richard Sims, BU