Oh interesting Sent from my iPhone On Nov 1, 2017, at 4:14 PM, fiber...@mail.com wrote: >> If I had four different colors of CWDM SFP modules, obviously I could use a >> CWDM Mux to connect all of them to the same fiber. Would a >> 1x4 PLC splitter also work? > No, because the CWDM SFP RX side is not wavelength selective. That's why you > use the demux to separate the wavelengths. > > Jared
Re: [AFMUG] WDM Stupid Question
> If I had four different colors of CWDM SFP modules, obviously I could use a > CWDM Mux to connect all of them to the same fiber. Would a > 1x4 PLC splitter also work? No, because the CWDM SFP RX side is not wavelength selective. That's why you use the demux to separate the wavelengths. Jared
[AFMUG] WDM Stupid Question
This occurred to me the other day. If I had four different colors of CWDM SFP modules, obviously I could use a CWDM Mux to connect all of them to the same fiber. Would a 1x4 PLC splitter also work? All 4 SFP's would receive all 4 wavelengths, but wouldn't they only respond to the one wavelength they're coded for? You could do something like that with radios if you had sufficient frequency separation. Just curious.