multiple LTOs in the same library
This mailing list seems dead. Is anybody actually still reading it? ___ Hello everyone, I have an Amanda setup nicely working with a SpectraStack. The drives are LTO8 but I've just figured out that there are several LTO7 too in the library. Now I've both types defined in amanda.conf however I cannot find a way to tell Amanda that tape labelled XXX or with the barcode 101010 is an LTO7 while another is an LTO8 instead. I've seen something around like specifying the blocksize in the tapelist file but didn't convince me moreover I didn't manage to find one example of such case despite I don't think this is such a rare case with libraries with a lot of tapes. I'm using amanda 3.3.3. I know is terribly old but we are going to do a major upgrade within months. In the meantime I'd like to implement this configuration, if possible. Any hint would be highly appreciated. Many thanks in advance.
Re: multiple LTOs in the same library
Someone is reading it. Maybe nobody knows the answer... Diego Il 16/05/2023 10:40, ASV ha scritto: This mailing list seems dead. Is anybody actually still reading it? ___ Hello everyone, I have an Amanda setup nicely working with a SpectraStack. The drives are LTO8 but I've just figured out that there are several LTO7 too in the library. Now I've both types defined in amanda.conf however I cannot find a way to tell Amanda that tape labelled XXX or with the barcode 101010 is an LTO7 while another is an LTO8 instead. I've seen something around like specifying the blocksize in the tapelist file but didn't convince me moreover I didn't manage to find one example of such case despite I don't think this is such a rare case with libraries with a lot of tapes. I'm using amanda 3.3.3. I know is terribly old but we are going to do a major upgrade within months. In the meantime I'd like to implement this configuration, if possible. Any hint would be highly appreciated. Many thanks in advance. -- Diego Zuccato DIFA - Dip. di Fisica e Astronomia Servizi Informatici Alma Mater Studiorum - Università di Bologna V.le Berti-Pichat 6/2 - 40127 Bologna - Italy tel.: +39 051 20 95786
Re: multiple LTOs in the same library
OK! I guess you have no hint for me but thanks anyway for giving a sign. On Tue, 2023-05-16 at 11:01 +0200, Kees Meijs | Nefos wrote: > Yes. > > On 16-05-2023 10:40, ASV wrote: > > This mailing list seems dead. Is anybody actually still reading it? >
Re: multiple LTOs in the same library
I think the settings you want are two different storage/pools sections with a labelstr regex for matching valid tapes for it. I cant see my config from my phone but its something like that. On Tue, 16 May 2023, 11:17 ASV, wrote: > OK! I guess you have no hint for me but thanks anyway for giving a > sign. > > On Tue, 2023-05-16 at 11:01 +0200, Kees Meijs | Nefos wrote: > > Yes. > > > > On 16-05-2023 10:40, ASV wrote: > > > This mailing list seems dead. Is anybody actually still reading it? > > > > >
Re: multiple LTOs in the same library
Thanks exuvo, I'll try to dig a bit in that direction even though I was expecting some built-in functionality for that. On Tue, 2023-05-16 at 12:16 +0200, Exuvo wrote: > I think the settings you want are two different storage/pools > sections with a labelstr regex for matching valid tapes for it. I > cant see my config from my phone but its something like that. > > > On Tue, 16 May 2023, 11:17 ASV, wrote: > > OK! I guess you have no hint for me but thanks anyway for giving a > > sign. > > > > On Tue, 2023-05-16 at 11:01 +0200, Kees Meijs | Nefos wrote: > > > Yes. > > > > > > On 16-05-2023 10:40, ASV wrote: > > > > This mailing list seems dead. Is anybody actually still reading > > > > it? > > > > > > >
Re: multiple LTOs in the same library
Am 16.05.23 um 16:34 schrieb ASV: Thanks exuvo, I'll try to dig a bit in that direction even though I was expecting some built-in functionality for that. Are the LTO7-tapes always in defined slots? As far as I understand all *drives* are LTO8, but not all *tapes* ?