Author:
Mike.Finn

Message:
WAS 7, with WMQ (6.x) based Activation Spec. I have an MDB connected to the AS 
and want to stop the listener for it on a programmatically detected failure (by 
setting rollback or unchecked exception), but I have not been able to make this 
work. It seems I can either get the messages to system exception queue, but 
that's about it. We need to preserve order and I can't have some messages in 
the sys exc queue and the MDB start working again (connecting to another 
system) and processing messages without the 'failed' messages first.

I know this is possible with a listener port, but there is an open issue with 
WAS requiring 7.0.0.5 upgrade (EJB3 MDB w/ 'deprecated' listener port), which 
is not an option for us at this point. 

http://www-01.ibm.com/support/docview.wss?rs=180&uid=swg1PK86005


Has anyone gotten this to work? 

Thanks,
Mike

To respond to this post, please click the following link:
<http://www.ibm.com/developerworks/forums/thread.jspa?messageID=14340557>

____________________________________
Unsubscribe via the "binocular" icon on the web

Reply via email to