Michael an additional follow up, I get the same "You have not entered a correct username and/or password. Please try again. " if I try to access a websites siteadmin. It almost seems as if some user permission file is messed up. I can access the server via ssh with the admin and the root. I can access email for admin via pop3, I can access websites wordpress dashboards and mysql is running ok, just appears to be issue with the gui and the ftp. Also I do not get that error any longer in /var/log/admserv/adm_error
[Wed Mar 21 08:27:14 2012] [error] [client 209.2.254.220] ServerScriptHelper.ServerScriptHelper(): Cannot authenticate to CCE (login name: , session ID: ) Bill > Hi Bill, > >> Unfortunately that didnt work.When i used that it still kicks me to the >> "Welcome and thank you" screen. If I use it on a different server running >> same version of Blue Onyx it works as you said it would. When I tried >> clicking on the start button I can see it is going to loginHandler then >> to >> login then back to intro.html. >> >> Its almost as if when I was adding the new site some config file got >> currupted. The new site i was adding used the same ip as an existing site >> on that server. > > That's fine. You can have as many sites on the same IP as you want. But > only > one of the sites is then allowed to use SSL certificates. > > Try this: > > Login as "admin" by SSH and "su -" to gain root access. > > Then run this programm: > > /usr/sausalito/bin/cceclient > > It will reply something like this: > > 100 CSCP/0.80 > 200 READY > > Then type this inside that program and be sure to type it with the same > upper > and lower cases as shown in my examples: > > find System > > It will reply something like this: > > 104 OBJECT 3 > 201 OK > > Note that it said that the object ID is 3. Yours may be different. Take a > look > at the object by using the "get" command. Be sure to use the object ID > that > the "find" command had reported: > > get 3 > > 102 DATA productBuild = "5108R" > 102 DATA NAMESPACE = "" > 102 DATA productIdentity = "20110922" > 102 DATA CLASSVER = "1.2" > 102 DATA isRegistered = "0" > 102 DATA CLASS = "System" > 102 DATA gateway = "192.0.2.1" > 102 DATA serialNumber = "" > 102 DATA domainname = "smd.net" > 102 DATA productName = "BlueOnyx 5107R/5108R" > 102 DATA productBuildString = "build 20110922 for a 5108R in en_US" > 102 DATA isLicenseAccepted = "1" > 102 DATA OID = "3" > 102 DATA productLanguage = "de_DE" > 102 DATA productSerialNumber = "" > 102 DATA console = "1" > 102 DATA productVendor = "" > 102 DATA dns = "&192.168.2.1&" > 102 DATA hostname = "5108r" > 102 DATA locales = "&en_US&da_DK&de_DE&ja_JP&" > 201 OK > > What we're looking for is this setting inside the "System" object: > > 102 DATA isLicenseAccepted = "1" > > In your case it is most likely set to "0" instead of "1". > > So do this (and be sure to replace the object number after the "set" with > the > object number that was reported to you during the "find" command: > > set 3 isLicenseAccepted = "1" > > If you typed that correctly, it will just reply back with this: > > 201 OK > > Press CTRL+C to exit cceclient. You should be able to get to the GUI now > without seeing the "Start" page. > > -- > With best regards > > Michael Stauber > _______________________________________________ > Blueonyx mailing list > Blueonyx@mail.blueonyx.it > http://mail.blueonyx.it/mailman/listinfo/blueonyx > _______________________________________________ Blueonyx mailing list Blueonyx@mail.blueonyx.it http://mail.blueonyx.it/mailman/listinfo/blueonyx